Connection with the mains
Connect the device to the mains with the power plug. The occupation of the connection cables is as follows:
Cable
Pin
Brown
Live
Blue
Neutral
Yellow/Green Earth
Attention! The earth has to be connected!
If the device will be directly connected with the local power supply network, a disconnection switch with a
minimum opening of 3 mm at every pole has to be included in the permanent electrical installation.
The device must only be connected with an electric installation carried out in compliance with the IEC
standards. The electric installation must be equipped with a Residual Current Device (RCD) with a maximum
fault current of 30 mA.
Please note: A maximum of 8 devices may be linked together. After every 8 devices, the fixtures must have
Master/Slave operation
The master/slave operation enables that several devices can be synchronized and controlled by one master
device.
On the rear panel of the device you can find an XLR jack and an XLR plug, which can be used for
connecting several devices.
Choose the device which is to control the effects. This device then works as master device and controls all
other slave devices, which are to be connected to the master device via a DMX-cable. Connect the OUT jack
with the IN plug of the next device.
Set the DMX start address 001 on every slave-device.
OPERATION
After you connected the effect to the mains, the strobe starts running.
The display lights up and you can choose the desired mode via the buttons MODE, ENTER, UP and DOWN.
The device features a built-in microphone and a rotary-control on the rear panel to adjust the sound
sensitivity.
The device has two operating modes. It can be operated in Stand Alone or in DMX-controlled mode.
- STAND-ALONE MODE
Setting flash-rate (S 0 – S100)
Setting brightness (d 0 – d100)
Sound Control / Sensitivity (SUND)
Slave Setting (d001)
- DMX MODE (d 1-512)
Stand-alone Mode
In the Stand Alone mode, the device can be used without a controller. Disconnect the device from the
controller.
International