10 Notes on wiring

10.1

Alarm centre

1
Terminal connector strip for tamper and alarm
COM A/T: Connections for detector tampering
CCT 1...8: Connections for alarm zones 1–8
2
Terminal connector strip for 12V DC power supply of
external equipment (e.g., detectors)
AUX:
+12V permanent voltage for detectors
0V:
0V ground
3
Terminal connector strip for loudspeaker, progr. outputs and
siren tampering.
TR:
Sabotage inputs
+ / LS:
Contact for optional 16 Ohm loudspeaker
OP3:
Contact for Open Collector Transistor output
(e.g. as trigger signal of dialler)
RELAY
OUTPUTS:Connections for 2 relays NC/NO
4
Terminal strip for control units
12V:
12V+ permanent voltage
0V:
0V ground
Data:
Databus
Clock:
Databus