Herunterladen Inhalt Inhalt Diese Seite drucken

Retrofit Image Input And Output Signals; Input Signals - Fronius Ri Fb Inside/I Bedienungsanleitung

Vorschau ausblenden Andere Handbücher für RI FB Inside/i:
Inhaltsverzeichnis
Verfügbare Sprachen

Verfügbare Sprachen

Retrofit Image Input and Output Signals

Input Signals

The signals listed below are available from firmware V1.6.0 for all Inside/i sys-
tems.
Only in Job mode (E17 - E32):
48
Serial no.
Signal designation
E01
Welding on
E02
Robot ready
E03
Operating mode bit 0
E04
Operating mode bit 1
E05
Operating mode bit 2
E06
E07
E08
E09
Gas test
E10
Wire forward
E11
Wire backward
E12
Error quit
E13
Position search
E14
Purge welding torch
E15
E16
E17 - E24
Job number
E25 - E31
Program number
E32
Welding simulation
E17 - E31
Job number
E32
Welding simulation
E33 - E40
Output set value - Low byte
E41 - E48
Output set value - High byte
Arc length correction, set value
E49 - E56
Low byte
Arc length correction, set value
E57–E64
High byte
E65 - E72
Pulse or dynamic correction
E73–E80
E81 - E88
E89 - E96
Range
Action
High
High
See table
Value
High
range for opera-
High
ting modes
on
page
49
High
High
High
High
High
High
High
0 to 99
1 to 127
High
0 to 999
High
0 to 65535
(0 to 100%)
0 to 65535
(-30 to +30%)
0 to 255
(-5 to +5%)

Kapitel

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Ri mod/i cc-m40 profinet