Setup menu
5.
Push the ECO button (B) to leave the menu. You can return to the setup menu by pushing the setup but-
ton (D) on the back of the room unit.
6.
Position the room unit where appropriate by using the provided screws. If the location of the unit has
not been confirmed, it can be placed in an upright position on a table, for example, as long as air can
circulate freely around it.
7.
For floor and radiator heating, select the desired indoor temperature. For constant temperature control,
select the supply water temperature. To adjust the temperature in either case, rotate the knob (A) and
confirm your choice with Enter (C) or wait for the set temperature to stop blinking on the display. Let the
device adjust to the settings for a few minutes.
38
2. VALVE
With the VALVE option you specify whether the valve opens in the clockwise or
the counter-clockwise direction. The default direction is clockwise (NOTE! the
arrow on the display).
3. RF
RF indicates the calculated average radio signal strength. The number changes
slowly, AND IF IT IS GROWING, EVERYTHING IS OK!
Recommendation: Wait for the RF reading to be at least over 50%!
4. DEFA
DEFA = resets the default settings!
NOTE! The DEFA option also resets the radio connection.
· If you select "YES", "RU" appears on the display.
· Before pairing can be started (by pushing the Enter button (C)) the trans-
former has to be briefly disconnected from the motor unit.
· If pairing is started before disconnecting the transformer, "FAIL" appears on the
display. In this case, disconnect the transformer from the motor unit for three
seconds. When the equipment powers on, it is available for pairing for five
minutes.