Herunterladen Diese Seite drucken

Vexve AM20-W Benutzeranleitung Seite 33

Vorschau ausblenden Andere Handbücher für AM20-W:

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 46
Transformer
· cable (2.5 m) included
· compatible with standard outlets and connects
to the motor unit connector A (see below for
when the power should be connected).
RF transmitter
Figure 2, page 2
· cable (1.5 m) with RJ connectors included
· connects to the motor unit connector C
· can be mounted on the wall with the provided
screw
· it should be located as high as possible in order
to ensure good communication
· there is a green/red LED on the transmitter that
indicates radio traffic.
NOTE! The power cable MUST NOT run next
to the RF transmitter or its cable!
www.vexve.com
Room unit
Figure 1, page 2
· the room unit runs on three (3) AA batteries, and
it is delivered with the batteries installed
· backlit LCD and rotating knob A for selecting
the desired temperature and navigating the
menus
· on the left, ECO button B for easily decreasing
the temperature during a workday or a holiday,
for example
· on the right, Enter button C for setting different
weekly programmes, monitoring the measured
indoor and supply water temperatures, viewing
the calculated supply water set point and valve
position, and specifying the minimum and maxi-
mum supply water temperatures
· setup button D embedded into the back panel
(can be pushed with the tip of a ballpoint pen):
a single push opens the setup menu, where you
can set the heating method and the direction of
valve rotation, check the radio signal strength,
and reset all the settings
· the battery cover also works as a wall-mounting
bracket (mounting screws included).
EN
33

Werbung

loading

Verwandte Produkte für Vexve AM20-W