Hazard information
Do not connect multiple pluggable switches into one another.
If the dimming actuator is operated with electronic transformers, only
those which meet the requirements of DIN EN 61347-1 (VDE 0712-30,
Part 1) along with DIN EN 61047 /VDE 0712-25, Part 2) may be used.
Only dimmable 230 V LED lamps may be used. Not dimmable 230 V
LED lamps may destroy the device and/or the light source.
Switching on of loads during power-on state (dimming level unequal
to 0) is not permitted. Doing so may generate very high inrush currents
that can destroy the device.
In order to avoid changes in the level of brightness, the device is able
to detect ripple control signals. However, short-time flickering of
the light source due to ripple control signals cannot be completely
excluded.
The dimming actuator is only suitable for light bulbs and high-volt-
age and low-voltage halogen lamps with electronic transformers as
well as dimmable LED lamps! Please only connect ohmic and ca-
pacitive lamp loads to the dimming actuator, and no televisions,
computers, motors etc.
Please note that 230V LED lamps may glow or flash while they are
switched off due to the very low power consumption.
The dimming actuator contains a thermal cut-off. Please note that in
the event of overheating the loads will be switched off completely.
Using the device for any purpose other than that described in this
operating manual does not fall within the scope of intended use and
shall invalidate any warranty or liability. This also applies to any
conversion or modification work. The device is intended for private
use only.
23