As-i universalmodul

Werbung

Function and features
The AS-i module operates as a slave in the AS-i network (AS-i profile:
S 0.0.F). It features 4 inputs (for 2-wire sensors or pnp 3-wire sensors).
• maximum number of modules per master: 31
• current supply from the AS-i-network, total 160mA per module
• sensor connection via PG7 cable glands and cage clamps
• AS-i interface via FC module lower part
AS-i flat cable yellow
Mounting
Address assignment by means of the addressing unit.
Fix the module onto the addressing unit. Assign a free address between
1 and 31; the as-supplied address is 0.
Mount the module onto the wired module lower part of the AS-i net-
work, tightening torque 0.8Nm.
Electrical connection
Disconnect the supply circuits.
Pass the sensor wires through the cable glands and connect them
to the cage clamps.
Do not connect the inputs with external potential.
Fonctionnement et caractéristiques
Ce module est un esclave dans le réseau AS-i (profil AS-i: S 0.0.F). Il
a 4 entrées (pour des capteurs 2 fils ou pnp 3 fils).
• nombre maximal de modules par maître: 31
• courant maxi total pour toutes les entrées: 160mA
• raccordement du capteur à l'aide des presses-étoupes PG7 et des
cages à ressort
• interface AS-i via les modules de câblage pour câble plat ou câble
rond
câble plat AS-i jaune
Montage
Affectation de l'adresse à l'aide de l'unité d'adressage.
Monter le module sur l'unité d'adressage. Affecter une adresse libre
entre 1 et 31; à la livraison l'adresse est 0. Monter le module sur
l'embase de câblage raccordé au réseau AS-i, couple de serrage
0,8Nm.
Raccordement électrique
Mettre les circuits d'alimentation hors tension.
Faire passer les câbles des capteurs par les presses-étoupes et rac-
corder les fils aux cages à ressort.
Ne pas raccorder les entrées à un potentiel externe.
LED yellow
LED green (AS-i power)
LED red
1 2 3
1 2 3 4
4
Pwr
Outputs
Inputs
1
1
2
2
3
3
4
4
tags for labelling
PG7 cable glands
LED jaune
LED verte
(alimentation AS-i)
LED rouge
1 2 3 4
1 2 3
4
Pwr
Outputs
Inputs
1
1
2
2
3
3
4
4
étiquettes
presse-étoupe PG7
Terminal connection and data bits
Input 1
Terminals
+
IN
D0
Data bit
Input
I+
I1
I-
Connect the sensors with the inputs I1 to I4.
I+ I1 I
I+ I2 I
I+ I3 I
I+ I4 I
mechanical
switch
Parameter bits: The parameter bits P0...P3 are not used.
Operation
Check the safe functioning of the unit. Display by LED's:
• LED PWR green is lit:
• LED's yellow are lit:
• LED PWR red is lit:
• LED PWR alternately
flashes green/red:
Raccordement et affectation des bits de données
Input 1
Borne
+
IN
D0
Bit de données
Entrée
I+
I1
I-
Raccorder les capteurs aux entrées I1 à I4.
I+ I1 I
I+ I2 I
I+ I3 I
I+ I4 I
fin de course
mécanique
Bits de paramètres:
Les bits de paramètres P0...P3 ne sont pas utilisés.
Fonctionnement
Vérifier le bon fonctionnement du module. Affichage par LED:
• LED PWR verte allumée:
• LED jaunes allumées:
• LED PWR rouge allumée: erreur de communication AS-i, esclave ne
• LED PWR clignote
vert/rouge en alternance: court-circuit de l'alimentation des capteurs
Input 2
Input 3
+
IN
+
IN
D1
D2
I+
I2
I-
I+
I3
I-
3-wire
PNP sensor
voltage supply via the AS-i network O.K.
inputs switched
AS-i communication error, slave does not
participate in the "normal" data exchange,
e. g. slave address 0
peripheral fault, e.g. overload or
short circuit of the sensor supply
Input 2
Input 3
+
IN
+
IN
D1
D2
I+
I2
I-
I+
I3
I-
3 fils
capteur PNP
alimentation via le réseau AS-i o.k.
entrées commutées
participe pas à l'échange "normal" des
données, p. ex. adresse d'esclave 0
défaut périphérique, p.ex. surcharge ou
Input 4
+
IN
D3
I+
I4
I-
Input 4
+
IN
D3
I+
I4
I-