Herunterladen Diese Seite drucken

RADEMACHER RolloTube DuoFern Kurzanleitung Zur Montage- Und Erstinbetriebnahme Seite 2

Rohrmotor

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

RolloTube DuoFern tubular motor
Brief instructions for installation and initial commissioning
These instructions describe the simplest way to configure the RolloTube DuoFern tubular motor. Please ensure that you refer to the full operating
instructions for the safety instructions, additional configuration options, connection options and information about resetting the system.
CAUTION!
Risk of crushing injuries due to rotating shaft!
There is a risk of crushing injuries to the hands when working with the roller shutter box open.
never reach into the area of the rotating union when the motor is running.
Stopper
(Fig. 1)
DANGER!
Risk of fatal electric shock!
Danger due to electric shock when working on
all electrical systems.
Only allow qualified specialists to work on
the electrical systems.
Switch off the power supply prior to car-
rying out installation work.
Keep moisture away from live equipment.
Manual central operating unit
1. Open the menu of the central operating unit by
pressing the M button.
2. Select system settings
Select menu item 2-1 connect / disconnect
3. The number of assigned devices is displayed.
4. Now press the Up key, in order to activate login
mode on your manual central operating unit.
5. Subsequently select the group and member number
and confirm in each case with OK until assigned
appears.
6. Exit the menu by pressing the M button.
Now move the motor upwards using the previously assigned transmitter (de-
pending on the installation, it may be necessary to press the up or down button).
The end point setting and the assignment for the direction of rotation is carried
out automatically (please refer to the figure for the program sequence).
IMPORTANT! Please do not press any other buttons during the
configuration process!
The roller shutter curtain must be equipped with a stopper or end rail in order to
undertake the subsequent automatic end point setting (Fig. 1).
In addition, the catch must be mounted so it can free-wheel. Sufficient free-
wheeling is given if the catch can be easily turned back and forth (supplied state
Fig. 2).
230 Volt~
50 Hz
1. Press the button on the motor head until the set button
LED flashes red and the motor advances briefly. You
now have 60 seconds to activate login mode from one
of the following transmitters.
and confirm with OK.
The motor acknowledges successful assignment by starting up briefly and the set button LED turns green.
M
~
L1
N
5
2 1 3 4
PE
L1
N
PE
IMPORTANT! If the "external switch" lead is not used, then it must be connected
to the neutral conductor!
NOTE!
If the button on the motor head is not acces-
sible, you can alternatively enter the DuoFern
code on the manual central operating unit
under menu item 2-2 and use the up key to
switch login mode to ON.
The DuoFern code is only active for 2
hours after switching on the power supply.
or
Manual transmitter
IMPORTANT!
1. First move the roller shutter upwards when automatically
2. The roller shutter should remain at the upper
The end points cannot be correctly adjusted if the two condi-
tions are not met. In this case, reset the tubular motor to its
The motor is now
factory settings and repeat the process.
fully configured and is
ready for operation.
(Fig. 2)
1
2
3
4
5
1 = L1 phase = black
2 = N neutral = blue
3 = External switch = white/grey
4 = Antenna = brown
5 = PE protective earthing conductor = green-yellow
or
Briefly press
the "connect
button" (see
arrow). Subse-
quently select
channel key
1-6.
adjusting the end points.
following automatic adjustment.
VBD 560-9-1 (05.18)
Wall transmitter
Press and
hold the two
above buttons
simultane-
ously until the
green LED
LED
flashes
end point

Werbung