Important
For call and door release operation,
and illumination of the call button/
info module, a separate transformer
with 12 V AC and sufficient output
is required.
Mounting
1 Disconnect from the mains before
opening the housing
2 Unscrew the two upper and lower
screws and take off the upper part
of the housing
3 The two provided heavy gauge
cable glands must be inserted into
the provided holes
4 Fix the appliance in such a way
that the cable enters from below
5 Thread the mains and light current
cable through the heavy gauge
cable glands from below and con-
nect as follows.
Grey terminals: N and L 1 (mains)
Yellow/green terminal. PE
(protective earth)
Blue terminal: "-" potential
Orange terminal: "+" potential
(12 V DC)
Putting into operation
The NG 404-0/NG 404-1 unit is de-
signed for use in Siedle communica-
tion systems for wall mounting.
When creating the electronic con-
nection, comply with the VDE 0805/
EN 60950 requirements.
The maximum ambient temperature
(TU) is +40°C.
The drawn output power must not
exceed 48 W.
In order to disconnect the appliance
from the supply circuit, a double-
pole disconnecting device with a
contact gap of ≥ 3 mm must be
provided in the appliance installation
(mains plug also possible).
Before removing the housing
cover, disconnect from the
mains.
Ensure that the terminal in the
appliance installation is fused with a
maximum of 16 A.
Specifications for NG 404-0
• Mains voltage 230 V AC 50/60Hz
• Primary fuse T 0.5 A
• Secondary voltage 12 V DC 3 A
short-circuit proof adjustable bet-
ween 9 V and 13 V, for this, con-
nect voltmeter between "+" and "-
• Output power max. 48 W
• Ambient temperature TU
max. + 40°C
• Approvals VDE 0805/EN 60950/
IEC 950
• Protection class IP 20
• Dimensions metal housing:
152 x 202 x 122 mm
Specifications for NG 404-1
• Mains voltage 125 V AC 50/60 Hz
• Primary fuse T 1 A
• Secondary voltage 12 V DC 3 A
short-circuit proof adjustable bet-
ween 9 V and 13 V. For this, con-
nect volt-meter between "+" and "-
• Output Power max. 48 W
• Ambient temperature TU max.
+ 40°C
• Approvals VDE 0805/EN 60950/
IEC 950
• Protection class IP 20
• Dimensions metal housing:
152 x 202 x 122 mm
6 Assignment of power supply
units
* Necessary with Zentravox, door
and in-house telephone systems
Warning!
Electrical appliances must only
be installed and assembled by
qualified electricians!
Disregard of this instruction
could result in extreme danger
to health or even to life through
electric shock
Français
Installation
Application
Pour installations interphoniques du-
plex d'appel au secours dans les as-
censeurs, installations interphoni-
ques dupiex entre le Portier électri-
que et les postes intérieurs et/ou
entre les postes intérieurs ainsi que
pour les centrales téphoniques
duplex Siedle Zentravox
Attention
En cas d'utilisation du redresseur
secteur pour la téléphonie de poste
et la téléphonie intérieure ainsi
qu'en association avec la central
téléphonique Zentravox, il faut un
transformateur de sonnerie
12 V AC, 2 A min. supplémentaire
pour la fonction appel respective-
ment commande de gâche.
Vous trouverez les schémas de
branchement extérieur des
installations ci-dessus dans la
brochure "Téléphonie de Porte et
téléphonie intérieure, projection
et Installation".
Installation
Note
Les appareils électriques ne doi-
vent être montés et branchés
que par du personnel qualifié.
Pendant l'installation, veuillez
respecter les consignes conçernant
la coupure de courrant.
Important!
Veuillez respecter le norme
DIN EN 60065!
Un interupteur bi-polaire avec une
distance de contact ouvert de mini-
mum 3 mm doit être présent dans
l'installation du bâtiment.
Matériel de câblage
Pour I'installation, vous pouvez utili-
ser du fil de sonnerie, du fil pour
courant basse tension ou du fil télé-
phonique.
Y
fil de sonnerie
YR
câble pour courant
basse tension
JY(ST)Y
paires torsadées,
blmdées
A2Y(ST)Y
câble de telecommuni-
cation souterrain
5

Werbung

loading

Diese Anleitung auch für:

Ng 404-1