6. There must be an even gap between the fi tting collar and the pipe
end. If necessary, the position of the fi tting must be adjusted using
a rubber mallet immediately after insertion.
Caution!
All sealing ribs of the fi tting must be covered by the pipe!
8. Attach the clamping tool.
Caution!
Do not tilt the tool! The tool must be fi tted so that the full surface area
is in contact and at a right angle!
Caution!
Failure to observe these instructions may result in damage to the
jointing system, in damage to the tool and to personal injury!
7. Cover the pipe evenly with REHAU lubricant around the full circum-
ference of the joint area.
Caution!
Only use REHAU lubricant!
9. By actuating the pressure pushbutton on the master cylinder, slide
the compression sleeve up to the fi tting collar.
If necessary, change the positions of the pins on the movable
clamping jaw to slide back the compression sleeve completely (see
sections Tool preparation/Pressing).