The long, movable clamping jaw has 2 pin positions. The fi rst position
is the start position, when the compression sleeve is still some
distance from the fi tting collar.
Caution!
Pins must be fully inserted.
The second position is the end position to slide the compression
sleeve right up to the fi tting collar.
Caution!
Pins must be fully inserted.
Pressing process for the size 125
The reducers for the size 125 are clipped into the clamping jaw 160.
e
Jointing system
SIZE 160
Abmessung 160
Caution!
Reducers must be fully clipped in.
e
SIZE 125
Abmessung 125
The set of reducers comprises one eccentric and one centric reducer.
Make sure that they are inserted with the eccentric reducer(s) up to
e
the joint (compression sleeve or fi tting collar).
SIZE 125
Abmessung 125