2.2 Accessories / Spare parts
Fig. 1.
Item
No.
Part
1.
Breathing hose
2.
Belt
2.
Belt PVC
3.
Hood excl. control valve
4.
Hood, bare
5.
Head harness
6.
Control valve SR 348
Repair kit
7.
Visor
8.
Frame
9.
Rubber stud (8 pcs)
10.
Screw (2 pcs)
11.
Protective cap
12.
Exhalation membrane
Flow meter. Fig 2
Protective film (3 pcs)
Compressed air filter SR 99-1. Fig. 12
Compressed air supply tube. See section 5.
3. Use
3.1 Installation
• Unroll the compressed air supply tube and make sure that it is
not twisted.
• Connect the breathing hose of the hood to the outlet of the
control valve. Fig. 3.
• Connect the compressed air supply tube to the control valve
inlet. Fig 4.
• The hood is now being supplied with air, and you can put it on.
If necessary, the width and height of the head harness can now
be adjusted. See 4.4.2.
3.2 Functional check
On every occasion before using the equipment:
• Check on the rated capacity of the compressed air system.
• Check the maximum number of users permitted.
• Check the number of users already connected.
Check that the minimum flow of air through the hood is at least
150 l/min.
Proceed as follows:
• Connect the breathing hose of the facepiece to the control valve.
Fig. 3
• Connect the compressed air supply tube to the control valve.
Fig. 4
• Turn the control valve knob anti-clockwise as far as it will go, in
order to throttle the air flow rate to a minimum. Fig. 3
• Place the hood in the bag and grip the opening of the bag so
that it seals around the breathing hose. Fig. 2.
• Grip the flow meter with the other hand and hold it so that it
points vertically up from the bag.
Read the position of the ball in the tube. It should float level with
or just above the marking on the tube.
If the flow rate is below the minimum value, check that
• The flow meter is vertical.
• The float can move freely.
• The air supply is not restricted by kinks or other restrictions in
the hoses.
3.3 Donning
• Put the belt on and adjust the length.
• Arrange the control valve in a way that allows easy adjustment
of the flow rate and a strict watch over the breathing hose, i. e.
it must not be placed on the back of the waist.
• Adjust the neck width of the hood by means of the elastic neck
strap.
20
• Use the control valve knob to set the air flow rate to suit the work
intensity. Fig. 3. In the fully closed position (turn anti-clockwise),
the flow is around 150 l/min, while in the fully open position (turn
clockwise), it is around 240 l/min.
Order No.
3.4 Doffing
R03-0311
R03-1510
Leave the work area before taking the hood off.
T01-3008
• Release the neck strap by releasing the buckle. Grip the top part
R03-0314
of the hood with both hands and pull the hood upwards/forward.
R03-0305
In emergency situations, the neck strap can be released without
R03-0322
releasing the buckle: Grip the neck strap with one hand on each
R03-0317
side of the buckle and pull firmly.
R03-0308
-
Releasing the compressed air tube / breathing hose
-
Both couplings are of safety type and are released in two stages.
-
Fig 5.
-
• Push the coupling towards the nipple.
-
• Pull the locking ring back.
-
4. Maintenance
R03-0346
R03-0105
H03-2810
Personnel who are responsible for maintenance of the equipment
-
must be trained and well acquainted with this type of work.
4.1 Cleaning
Sundström cleaning wipe SR 5226 is recommended for daily care. If
the equipment is heavily soiled, use a warm (up to +40 °C), mild soap
solution and a soft brush, followed by rinsing with clean water and
drying in air at room temperature. If necessary, spray the equipment
with 70 % ethanol or isopropanol solution for disinfection.
NOTE! Never use solvent for cleaning.
4.2 Storage
After cleaning, store the equipment in a dry and clean place at
room temperature. Avoid direct sunlight. The flow meter can be
turned inside out and be used as a storing bag.
4.3 Maintenance schedule
Recommended minimum requirements on maintenance routines
so you will be certain that the equipment will always be in usable
condition.
Visual inspection
Functional check
Cleaning
Change of breathing hose
4.4 Spare parts
Always use genuine Sundström parts. Do not modify the equip-
ment. The use of non-genuine parts or modification of the
equip ment may reduce the protective function and put at risk the
approvals received by the product.
4.4.1 To change the control valve
The control valve is a complete, sealed unit. Never attempt to
repair or modify it.
4.4.2 To change the visor/frame
Proceed as follows to change the visor/frame:
• Release the head harness which is secured by means of two
socket-head screws at the top corners of the frame.
• Pull off the 8 rubber studs, and remove the frame and visor.
• Straighten the frame or fit a new frame, and place it on a flat
surface with the short side towards you. Fit 4 studs into the two
furthest holes on each side. Fig. 6.
• Place the hood over the frame and insert the 4 studs into the
corresponding holes in the hood.
• Remove the protective films from the visor and from the double-
sided adhesive tape. Fig. 7, 8.
Before
After
Annually
use
use