➢ When the exhaust duct is connected horizontally, a minimum falling gradient of
1 cm/m or an inclination of 2° is required. Otherwise, condensate will get into
the motor of the hood.
➢ When an exhaust duct is used, the ending of the exhaust hose must be adjusted
into the direction of flow.
➢ If the exhaust duct passes through cool areas (e.g., an attic), a temperature
gradient may occur in the different parts of the exhaust duct so condensate will
be generated. Proper insulation of the corresponding parts of the exhaust duct
will then be needed. Equip such an exhaust duct with a condensate trap if need
be.
➢ Depending on the appliance model the hood is equipped with one (top) or
two (top, back) outlets. The idle outlet is covered by a plastic cap. You can remove
this cap by turning it anticlockwise. Use the cap to cover the idle outlet.
2.3 Minimum distances
Strictly observe the minimum distance between the extractor hood and the
hob.
It is also absolutely necessary to observe the individual minimum
distances between hobs and extractor hoods; these are specified in the
instruction manual of your hob / oven / etc.
ceramic-glass rings / hotplates
gas cookers
coal / oil / stove wood firing
1. The minimum distances do not represent the required total height, but a
minimum value generated by adding the height of the hob (floor ↔ hob) and the
required minimum distance of the hob to the extractor hood (hob ↔ extractor
hood)
2. Adapt the total installation height to the height of the user. Please note that the
extraction capacity of the appliance can decrease if installed at a large distance to
the hob.
R
EQUIRED MINIMUM DISTANCE HOOD TO
+
(hob ↔ extractor hood)
=
M
INIMUM INSTALLATION HEIGHT
(floor ↔ hob)
~ 60 ~
min. 65 cm
min. 75 cm
min. 85 cm