Maintenance and care
Load is not released
Gripping width cannot be
adjusted at all or cannot be
adjusted correctly
7.3

Repairs

Only persons with the appropriate knowledge and ability are allowed to repair the device.
Before the device is used again, it has to be checked by a qualified person or an expert.
54500008
Hook-up eyelet is in the wrong
position of the scenery
The dissolving power is not
sufficient
Foreign bodies in the mechanics
Foreign bodies on horizontal
shifting tubes
Dust or dirt on horizontal shifting
tubes
22 / 24
Check the position of the
suspension eye in the splitter.
To release, the suspension eye
must be in idle position (position
B, marked red).
Correct angle for release. See
chapter Operation "Optimum
pulling direction for opening the
device".
Check for possible foreign
bodies in the internal gearing
and remove them
Check for and remove any
foreign bodies on the horizontal
shifting tubes
Clean the horizontal shifting
tubes with a high-pressure
cleaner and lubricate if
necessary.