Herunterladen Diese Seite drucken

MCS Master DHP 55 Benutzer- Und Wartungsanleitung Seite 13

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 20
► THIS APPLIANCE IS NOT INTENDED FOR USE BY
PERSONS (INCLUDING CHILDREN) WITH REDUCED
PHYSICAL , SENSORY OR MENTAL CAPABILITIES,
OR LACK OF EXPERIENCE AND KNOWLEDGE , UN-
LESS THEY HAVE BEEN GIVEN SUPERVISION OR IN-
STRUCTION CONCERNING USE OF THE APPLIANCE
BY A PERSON RESPONSIBLE FOR THEIR SAFETY.
CHILDREN SHOULD BE SUPERVISED TO ENSURE
THAT THEY DO NOT PLAY WITH APPLIANCE.
► Please do not cut off the power by pulling the wire.
► Please do not plug or unplug to startup or shut off the
unit.
► Please be careful when moving the unit, do not man-
gle the wire.
► Please do not put fingers or sticks into the grid.
► Please prohibit child to climb, stand or sit on the unit.
► Please unplug the unit before cleaning or mainte-
nance.
SAFETY RELATING TO REFRIGERANT
R290:
► Read these warnings carefully.
► This appliance contains the refrigerant R290. R290
is a refrigerant that complies with the relevant European
Directives. Never perforate the refrigerant circuit. R290 is
flammable (GWP3)!
► Do not use means to accelerate the defrosting process
or to clean, other than those recommended by the manu-
facturer.
► The appliance shall be stored in a room without conti-
nuously operating ignition sources (for example: open fla-
mes, an operating gas appliance or an operating electric
heater).
► Do not pierce or burn any of the components of the
cooling circuit of the unit. Do not set light to the unit.
► The appliance shall be stored so as to prevent mecha-
nical damage from occurring.
► Appliance should be installed, operated and stored in
a room with a floor area larger than 4m
► Be aware that the refrigerants may not contain an
odour, which means you cannot smell leaks.
► Compliance with national gas regulations shall be ob-
served.
► Keep ventilation openings clear of obstruction.
► A warning that the appliance shall be stored in a
well-ventilated area where the room size corresponds to
the room area as specified for operation.
► Any person who is involved with working on or brea-
king into a refrigerant circuit should hold a current valid
certificate from an industry-accredited assessment au-
thority, which authorizes their competence to handle refri-
gerants safely in accordance with an industry recognized
assessment specification.
► Servicing shall only be performed on the grounds as
recommended by the equipment manufacturer. Mainte-
nance and repair requiring the assistance of other skilled
personnel shall be carried out under the supervision of the
person competent in the use of flammable refrigerants.
NOTICE: WE SUGGEST THAT ANY REPAIRS
SHOULD BE EXECUTED BY PROFESSIONAL
SERVICEMEN
► Please make sure the unit is grounded.
► Please do not use unit in airproof conditions.
► Please follow the instructions thoroughly.
PRODUCT INTRODUCTION
Dehumidifiers can reduce air humidity in room and thus
make people live comfortably and goods stored proper-
ly. Due to their neat appearance, compact configuration,
high quality and easy operation, our dehumidifiers are
widely used in research institutions, industry, transpor-
tation, medical centers, measuring institutions, stores,
underground constructions, computer rooms, archives,
warehouses, bathrooms, etc. Keeping apparatus, meters,
computers, communication equipments, drugs and files
away from moisture, eroding, and mildew.
►►
Dehumidifier PIC. 1
A. Control panel (display).
B. Cover.
C. Air outlet grille.
D. Wheels.
E. Transport handle. The handle must be installed by tightening
the screws located on the side of the dehumidifier (Pic. 1).
F. Cord reel hooks.
G. Air inlet grille (contains the air filter which must be cleaned
periodically. For cleaning remove the screws and remove the
filter panel, clean the filter with low pressure air).
H. Compartment for the drain pump or water recovery tank
(optional tank).
I. Drain pipe.
►►
The control panel (Pic. 2) is located on the front of the
dehumidifier and includes the following icons and buttons:
►3.1. "ON/OFF" button (A Pic. 2): This button is used to switch
►3.2. RELATIVE HUMIDITY (B Pic. 2): The indicated value is
►3.3. ROOM TEMPERATURE (C Pic. 2): The indicated value is
.
2
►3.4. DROP ICON (D Pic. 2): The "DROP" icon indicates when
►3.5. WATER DRAIN ICON (with acoustic signal) (E Pic. 2):
►3.6. DEFROST ICON (F Pic. 2): The "DEFROST" icon
►3.7. VENTILATION ICON (G Pic. 2): The "VENTILATION"
►3.8. TIMER (H Pic. 2): Displays the time (when the delayed
►3.9. "+" / "-" BUTTONS (I Pic. 2): These buttons are used to
►3.10. "LIGHT" BUTTONS (L Pic. 2): This button is used to turn
2. DESCRIPTION
3. CONTROL PANEL AND DISPLAY
the dehumidifier on or off.
the relative humidity in the room. When the desired humidity
value is set, the reference value will be shown on the display
for a few seconds.
the temperature in the room.
the dehumidifier is operating. When the "DROP" icon lights up
on the display, it means that the dehumidifier is dehumidifying.
If the "DROP" icon flashes on the display, it means that the
humidity in the room is lower than the humidity set on the
display and the dehumidifier, only the ventilation function will
work.
The "WATER DRAIN" icon (Error E4) indicates that the drain
pump is blocked. If the water recovery tank (OPTIONAL) is
used instead of the drain pump, it means that the tank is full
and must be drained manually.
indicates when the dehumidifier is defrosting (in this stage,
ventilation is stopped).
icon indicates when the dehumidifier is in ventilation mode.
switch-on or switch-off mode is set, the reference time for the
desired setting is displayed for a few seconds).
select the desired relative humidity in the room (by lowering
this value, the dehumidifier will increase performance).
on the display light for a few seconds, when the dehumidifier
is on.
en
it
de
es
fr
nl
da
fi
no
sv
pl
ru
cs
hu
sl
hr
lt
lv
et
ro
sk
bg
uk
zh
SI
SK
TR
UA

Werbung

loading

Diese Anleitung auch für:

Dhp 55dv