Herunterladen Diese Seite drucken

Miele DOS K 85 flex Montageanweisung Seite 16

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
en - Installation
Wall
mounting:
Surface
mounting:
16
Schematic diagram showing the dispensing module
 Dispensing problems caused by fitting the canister incorrectly.
The container must not be placed on top of or above the cleaning
machine. Make sure that the dispensing hose is not kinked or
trapped.
Place the canister on the floor next to the cleaning machine or in-
side an adjacent cabinet.
Fitting the dispensing module
The dispensing module is supplied with two screws (4.2 x 25 mm)
and two plugs (6 mm) for fitting.
Select a suitably accessible position, e.g. on an adjacent wall or in-
side a cabinet, for fitting the dispensing module.
Using the drawing as a guide, fit the screws the correct distance
apart (80.0 mm) and suspend the dispensing module from these.
Two slots 76.0 mm apart are provided at the bottom of the dispensing
module for fixing the module to a thin carrier or plate. Screws 3.9 mm
in diameter (not supplied) are required to secure the module.
Drill two holes through the plate and screw the dispensing module
firmly in place from underneath.