10.7 Inrush function
The inrush function permits recording of start-up currents within 100 ms (millisec-
onds) in the measuring function A-AC. The measurement takes place in the measur-
ing range of 300 A with a trigger current of 5 A.
Keep the button "INRUSH" pressed for approx. 2 seconds. Input is confirmed
by a beep.
– The display shows the symbol "INRUSH" togeth-
er with the current type "AC".
– Four dashes indicate readiness for measuring.
Connect the current probe to the object to be meas-
ured.
Switch on the object to be measured. Once the trig-
ger current of 5 A has been exceeded, the start-up current will be displayed. The
measured value remains on the display.
Push and hold (2 s) the button "Inrush" to return to the normal measuring func-
tion.
The inrush function is only available in AC current measuring operation.
The hold function is not available when the inrush function is active.
INRUSH
77