E R R O R M O D E S
The thermostat indicates a faulty condition by flashing the LEDs. The
most typical case is that the real time is distorted during a power in-
terruption that is too long. This is automatically fixed by connecting to
the ecoControl App. Possible error codes (visible on the info page of the
App) are:
1 Floor sensor error
2 Overheating
3 Internal error
10 Calendar time is not valid
You can try to fix the error by turning off the power to perform a soft
reset or by creating a hard reset with the ecoControl App.
In case of errors 1, 2, 3, the heating will be permanently switched off.
In error 10, the user program is disabled.