oPerATIoN
safety
2. Safety
2.1
Intended use
The appliance is a decentralised extractor. The appliance is
used to ventilate living spaces, sanitary facilities and domestic
kitchens to dIN 18017-3.
The appliance is intended for domestic use. It can be used safe-
ly by untrained persons. The appliance can also be used in
non-domestic environments, e.g. in small businesses, as long
as it is used in the same way.
Any other use beyond that described shall be deemed inappro-
priate. observation of these instructions and of the instructions
for any accessories used is also part of the correct use of this
appliance.
If the fan is to be operated in very harsh conditions, the manu-
facturer's approval is required. such conditions include excep-
tional climatic conditions or excessive contamination.
2.2 General safety instructions
WARNING Injury
!
The appliance may be used by children over 8 years
of age and persons with reduced physical, sensory
or mental capabilities or a lack of experience and
expertise, provided that they are supervised or they
have been instructed on how to use the appliance
safely and have understood the potential risks. Chil-
dren must never play with the appliance. Cleaning
and user maintenance must not be carried out by
children without supervision.
WARNING Injury
!
If there is a radio or police announcement ordering
windows and doors to be kept closed, disconnect
the appliance from the power supply.
WARNING Injury
!
Working on the appliance presents a risk of injury
from moving parts.
f Before starting any cleaning and maintenance
work, disconnect the appliance.
2.3 Test mark
see type plate on the appliance.
22 |
3. Appliance description
3.1
Function description
subject to demand, the humid, odorous air is transported out
of the bathroom and wC to the outdoors or into central extract
air shafts. This creates slight negative pressure in the apart-
ment. due to this negative pressure, fresh, filtered air flows in
of its own accord through air apertures in the external walls of
living spaces and bedrooms. overflow apertures in the doors
create an air connection between the supply and extract air
areas.
depending on the airtightness of the building, decentralised
external wall apertures in supply air areas are not essential. In
some cases, natural infiltration due to the permeability of the
building envelope provides sufficient fresh air.
Appliance with humidity sensor
when the humidity sensor detects a demand or when you
change to full load with a switch, the appliance changes to
the maximum possible air flow rate.
start delay
run-on time
Appliance without humidity sensor
The appliance operates at a fixed set air flow rate. when you
change to full load via a switch, the appliance changes to the
maximum possible air flow rate.
start delay
run-on time
3.2 Components
3.2.1 Flush-mounted installation
LA 60
Fan unit for installation in walls and
Ve-U
ceilings
LA 60
Flush-mounted enclosure without
G-U
fire protection
LA 60
Flush-mounted enclosure made of
G-UB
fire protection material
ZLA
Control system for connecting to the
60-T
fan unit. Adjustable start delay and
run-on time.
ZLA
Control system for connecting to
60-H
the fan unit. Humidity-dependent
control, with fixed start delay and
run-on time.
Fixed value
s
60
min
7
min.
Max.
s
3
150
min
3
30
LA 60
LA 60
LA
LA 60
U
UB
60 U
UB
Trend
Trend
Plus
Plus
x
x
x
x
x
x
x
x
x
x
x
x
LA 60 Trend | LA 60 Plus