Herunterladen Diese Seite drucken

Panasonic PAW-SERVER-PKEA V5.1 Installationsanleitung Seite 4

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Im Lieferumfang enthaltene Teile
1
A) PAW-SERVER-PKEA
B) CAB-SERV mit Stecker für
Innengeräteanschluss
Anschlussschema (sämtliche Teile innerhalb des
2
Computerraums)
Innengerät "A"
Included with
the indoor unit
KIT-E12-PKEA
KIT-E15-PKEA
CS-E12PKEA
CS-E15PKEA
CU-E12PKEA
CU-E15PKEA
3.50 (0.85-4.00)
4.20 (0.98-5.00)
3,010 (730-3,440)
3,610 (840-4,300)
4.02 (3.57-5.00)
A
3.50 (3.50-3.16)
6.7
A++
6.3
A++
3.5
4.2
0.87 (0.17-1.12)
1.20 (0.28-1.58)
183
233
4.00 (0.85-6.60)
5.40 (0.98-7.10)
3,440 (730-5,680)
4,640 (840-6,110)
4.78
5.14
4.35 (3.63-5.15)
3.75 (2.88-3.24)
A
4.1
3.9
A+
A
3.6
3.6
0.92 (0.165-1.82)
1.44 (0.34-2.19)
1229
1292
230
230
16
16
1.5
1.5
4 x 1.5
4 x 1.5
4.0 / 4.2
5.4 / 6.5
8.4
9.6
816 / 882
846 / 900
2,0
2.4
42 / 29 / 26 - 42 / 33 / 30
43 / 32 / 29 - 43 / 35 / 32
58 / 58
59 / 59
295 x 870 x 255
295 x 870 x 255
10
10
1974 / 1926
2052 / 1980
48 / 50
46 / 46
63 / 65
61 / 61
622 x 824 x 299
695 x 875 x 320
36
45
1/4" (6.35) / 3/8" (9.52)
1/4" (6.35) / 1/2" (12.70)
1,100
1.060
5
15
3 / 15
3 / 15
7.5
7.5
20
20
Fernbedienung
-15 / +43
-15 / +43
-15 / +24
-15 / +24
Down to
Down to
Easy
-15 ºC
-15 ºC
control
in
in
cooling mode
heating mode
by BMS
OUTDOOR
OUTDOOR
CONNECTIVITY
TEMPERATURE
TEMPERATURE
Down to -15 °C in
Down to -15 °C in
The communication port is
cooling only mode The
heating mode The air
integrated into the indoor unit and
air conditioner works
conditioner works in
provides easy connection to, and
in cooling only mode
heat pump mode with an
control of, your Panasonic heat
with an outdoor
outdoor temperature as
pump to your home or building
temperature of -15 °C.
low as -15 °C.
management system.
WALL MOUNTED PROFESSIONAL
INVERTER -15 °C ON COOLING MODE
KIT-E9-PKEA // KIT-E12-PKEA // KIT-E15-PKEA
// KIT-E18-PKEA
OUTDOOR FEATURES
· Cooling from as low as ambient -15 °C
· Electronic expansion valve (accurate sub-cooling
and adjustable refrigerant flow)
· Outdoor DC fan motor to provide flexible air-flow
to ensure optimum condensation pressure (work
CAB-SERV
CU-E9PKEA
CU-E15PKEA
on outdoor pipe temperature sensor)
CU-E12PKEA
CU-E18PKEA
KIT
KIT-E18-PKEA
Indoor
CS-E18PKEA
Outdoor
CU-E18PKEA
Cooling capacity
5.00 (0.98-6.00)
Nominal (Min - Max)
4,300 (840-5,160)
Nominal (Min - Max)
EER
Nominal (Min - Max)
A
1)
3.47 (3.50-3.02)
A
SEER
Nominal
6.9
A++
Pdesign (cooling)
5.0
Power input Cooling
1.44 (0.28-1.99)
Nominal (Min - Max)
Annual electricity consumption (cooling)
254
2)
Heating capacity
5.80 (0.98-8.00)
Nominal (Min - Max)
4,990 (840-6,880)
Nominal (Min - Max)
Heating capacity at -7°C
5.80
Nominal
COP
Nominal (Min - Max)
1)
3.82 (2.88-3.11)
A
A
SCOP
Nominal
4.2
A+
P Design at -10 °C
4.4
Power input Heating
1.52 (0.340-2.57)
Nominal (Min - Max)
Annual electricity consumption (heating)
1467
2)
Indoor Unit
Power source
230
Recommended Fuse
16
Recommended power cable section
1.5
Connection indoor / outdoor
4 x 2.5
Current (Nominal)
6.4 / 6.8
Cooling / Heating
Max. Current
11.3
Air Volume
1074 / 1158
Cooling / Heating
Moisture removal volume
2.8
Sound pressure Level
44 / 37 / 34 - 44 / 37 / 34
3)
Cooling - Heating (Hi / Lo / S-Lo) dB(A)
Sound power Level
60 / 60
Cooling / Heating (Hi)
Dimensions
295 x 1070 x 255
H x W x D
Net weight
13
Outdoor Unit
Air Volume
2352 / 2274
Cooling / Heating
Sound pressure Level
47 / 47
Cooling / Heating (Hi)
3)
Sound power Level
61 / 61
Cooling / Heating (Hi)
Dimensions
4)
695 x 875 x 320
H x W x D
Net weight
46
Piping connections
1/4" (6.35) / 1/2" (12.70)
Liquid / Gas pipe
Refrigerant Loading
1.240
R410A
Elevation difference (in/out)
15
Max
Piping length
3 / 20
Min / Max
Precharge length
7.5
Max
Additional charge
20
Operating range
-15 / +43
Cooling Min / Max
-15 / +24
Heating Min / Max
Rating Conditions: Cooling Indoor 27 °C DB / 19 °C WB. Cooling Outdoor 35 °C DB / 24 °C WB. Heating Indoor 20 °C DB. Heating Outdoor 7 °C DB / 6 °C WB. (DB: Dry Bulb; WB: Wet Bulb)
1) EER and COP classification is at 230 V in accordance with EU directive 2002/31/EC. 2) The annual energy consumption is calculated in accordance with the ErP directive. 3) The Sound pressure level of the units shows the value measured of a position 1 meter in front of the main
body and 0,8 m below the unit. The sound pressure is measured in accordance with Eurovent 6/C/006-97 specification. 4) Add 70 mm for piping port.
Specifications subject to change without notice.
For detailed information about ErP, please visit our page http://www.doc.panasonic.de
A
Internet
class
5 year
Control
energy saving
compressor
Ready
warranty
ROTARY
INVERTER COMPRESSOR
INTERNET CONTROL
Internet Control is a next generation
New Panasonic R2 Rotary
Inverter System. The Inverter range provides greater
5 Years Warranty.
system providing a user-friendly
Compressor. Designed to withstand
efficiency, more comfort and less noise than classic air
We guarantee the
remote control of air conditioning or
extreme conditions, Panasonic
conditioners. The Inverter system provides more precise
compressors in
heat pump units from everywhere,
Rotary delivers high performance,
temperature control, and keeps the ambient
the entire range
using a simple Android or iOS
efficiency and reliable service, no
temperature constant with lower energy consumption
for five years.
smartphone, tablet or PC via internet.
matter where you are.
and a significant reduction in noise and vibration levels.
Detail 1
KIT-E9-PKEA
CS-E9PKEA
CU-E9PKEA
kW
2.50 (0.85-3.00)
Kabel 4 x 0,22 mm², geschirmt max. Länge: 5 m
kCal/h
2,150 (730-2,580)
Energy Saving
4.85 (4.23-5.00)
A
Energy Saving
7.1
A++
kW
2.5
kW
0.515 (0.17-0.71)
kWh
123
kW
3.40 (0.85-5.40)
kCal/h
2,920 (730-4,640)
kW
3.91
Energy Saving
4.86 (4.12-5.15)
A
Energy Saving
4.4
A+
kW
2.8
kW
0.7 (0.165-1.31)
kWh
891
V
230
A
16
mm²
1.5
mm²
4 x 1.5
A
2.5 / 3.3
A
7.8
m³/h
798 / 876
l/h
1.5
39 / 26 / 23 - 40 / 27 / 24
dB
55 / 56
mm
295 x 870 x 255
kg
10
m³/h
1878 / 1782
dB(A)
46 / 47
dB
61 / 62
mm
622 x 824 x 299
kg
36
inch (mm)
1/4" (6.35) / 3/8" (9.52)
kg
1,100
Potenzialfreie Kontakte
m
5
m
3 / 15
2 E / 4 A
m
7.5
g/m
20
°C
-15 / +43
°C
-15 / +24
7.1 A++
4.4 A+
SEER
SCOP
SEASONAL ENERGY
SEASONAL COEFFICIENT
EFFICIENCY RATIO
OF PERFORMANCE
Exceptional Seasonal Cooling
Exceptional Seasonal Heating
Efficiency based on the new
Efficiency based on the new
ErP regulation. Higher the
ErP regulation. Higher the
SEER ratings mean greater
SCOP ratings mean greater
efficiency. Save all the year
efficiency. Save all the year
while cooling!
while heating!
Innengerät "B"
Included with
CAB-SERV
the indoor unit
KIT-E12-PKEA
KIT-E15-PKEA
CS-E12PKEA
CS-E15PKEA
CU-E12PKEA
CU-E15PKEA
3.50 (0.85-4.00)
4.20 (0.98-5.00)
3,010 (730-3,440)
3,610 (840-4,300)
4.02 (3.57-5.00)
A
3.50 (3.50-3.16)
6.7
A++
6.3
A++
3.5
4.2
0.87 (0.17-1.12)
1.20 (0.28-1.58)
183
233
4.00 (0.85-6.60)
5.40 (0.98-7.10)
3,440 (730-5,680)
4,640 (840-6,110)
4.78
5.14
4.35 (3.63-5.15)
3.75 (2.88-3.24)
A
4.1
3.9
A+
A
3.6
3.6
0.92 (0.165-1.82)
1.44 (0.34-2.19)
1229
1292
230
230
16
16
1.5
1.5
4 x 1.5
4 x 1.5
4.0 / 4.2
5.4 / 6.5
8.4
9.6
816 / 882
846 / 900
2,0
2.4
42 / 29 / 26 - 42 / 33 / 30
43 / 32 / 29 - 43 / 35 / 32
58 / 58
59 / 59
295 x 870 x 255
295 x 870 x 255
PAW-SERVER-PKEA
10
10
1974 / 1926
2052 / 1980
48 / 50
46 / 46
63 / 65
61 / 61
622 x 824 x 299
695 x 875 x 320
36
45
1/4" (6.35) / 3/8" (9.52)
1/4" (6.35) / 1/2" (12.70)
1,100
1.060
5
15
3 / 15
3 / 15
7.5
7.5
Detail 2
20
20
-15 / +43
-15 / +43
-15 / +24
-15 / +24
Down to
Down to
Easy
-15 ºC
-15 ºC
control
in
in
cooling mode
heating mode
by BMS
OUTDOOR
OUTDOOR
CONNECTIVITY
TEMPERATURE
TEMPERATURE
Down to -15 °C in
Down to -15 °C in
The communication port is
cooling only mode The
heating mode The air
integrated into the indoor unit and
air conditioner works
conditioner works in
provides easy connection to, and
in cooling only mode
heat pump mode with an
control of, your Panasonic heat
with an outdoor
outdoor temperature as
pump to your home or building
temperature of -15 °C.
low as -15 °C.
management system.
CU-E9PKEA
CU-E15PKEA
CU-E12PKEA
CU-E18PKEA
KIT-E18-PKEA
CS-E18PKEA
CU-E18PKEA
5.00 (0.98-6.00)
4,300 (840-5,160)
A
3.47 (3.50-3.02)
A
6.9
A++
5.0
1.44 (0.28-1.99)
254
5.80 (0.98-8.00)
4,990 (840-6,880)
5.80
3.82 (2.88-3.11)
A
A
4.2
A+
4.4
1.52 (0.340-2.57)
1467
230
16
1.5
4 x 2.5
6.4 / 6.8
11.3
1074 / 1158
2.8
44 / 37 / 34 - 44 / 37 / 34
60 / 60
295 x 1070 x 255
13
2352 / 2274
47 / 47
61 / 61
695 x 875 x 320
46
1/4" (6.35) / 1/2" (12.70)
1.240
15
3 / 20
7.5
20
-15 / +43
-15 / +24
5 year
compressor
warranty
ROTARY
INVERTER COMPRESSOR
New Panasonic R2 Rotary
5 Years Warranty.
Compressor. Designed to withstand
We guarantee the
extreme conditions, Panasonic
compressors in
Rotary delivers high performance,
the entire range
efficiency and reliable service, no
for five years.
matter where you are.

Werbung

loading