Herunterladen Diese Seite drucken
Danfoss ERC 211 Installationsanleitung
Vorschau ausblenden Andere Handbücher für ERC 211:

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 130
Installation Guide
ERC 211
Digital controller for refrigeration and defrost, 1 relay.

Werbung

loading

Inhaltszusammenfassung für Danfoss ERC 211

  • Seite 1 Installation Guide ERC 211 Digital controller for refrigeration and defrost, 1 relay.
  • Seite 2 Dimensions (mm) and Mounting 61.2 Drilling template Rear mounting (lock with clips) Mounting Dismounting Installation Guide | ERC 211 DKRCE.PI.RL0.F7.ML...
  • Seite 3 Electrical Connections Quick programming tool: EKA 183B Sair Connectors: Max. Torque = 0.4 Nm Sair Sc/DI1 Power supply (according to the product code number) DKRCE.PI.RL0.F7.ML Installation Guide | ERC 211...
  • Seite 4 The ERC 211 is a smart, multipurpose integrated refrigeration controller with temperature and defrost management, available with 1 relay. This controller is for Operating temperature sensing control, suitable for refrigeration and heating applications. Incorporated control has been designed to fulfil today’s requirements for commercial refrigeration applications.
  • Seite 5 Press for one second: DOWN TEMPERATURE SETPOINT/OK Press and hold: DEFROST Press and hold: MENU Display Icons Night mode Fan running Defrost (Energy saving) Compressor running Active alarm Unit (°C or °F) Flashes in pull-down mode DKRCE.PI.RL0.F7.ML Installation Guide | ERC 211...
  • Seite 6 Medium temperature (2 – 6 °C), with timed natural defrost App 3 Medium temperature (2 – 6 °C), with natural defrost stop on air temperature App 4 Heating Thermostat (20 – 60 °C) App 5 None (no preset application) with simplified parameter list Installation Guide | ERC 211 DKRCE.PI.RL0.F7.ML...
  • Seite 7 The display shows the default value (eg. “n10” flashing). Choose sensor type by pressing UP/DOWN (n5=NTC 5 K, n10=NTC 10 K, Ptc=PTC, Pt1=Pt1000) and press SET to confirm. NOTE: All sensors must be the same type. DKRCE.PI.RL0.F7.ML Installation Guide | ERC 211...
  • Seite 8 4 - Menu structure Installation Guide | ERC 211 DKRCE.PI.RL0.F7.ML...
  • Seite 9 - Press SET to access the “o61” parameter. - Press UP/DOWN to select an application (AP0= no application selected). - Press SET to confirm, “o61” is displayed. Continue to set the next parameters (“o06” sensor type) in the “cFg” menu. DKRCE.PI.RL0.F7.ML Installation Guide | ERC 211...
  • Seite 10 SET: save the temperature setpoint. Initiate a manual defrost DEFROST: press for 3 seconds to initiate a defsost. DEFROST: press for 3 seconds to stop manual defrost. The DEFROST icon is shown during defrost. | 10 Installation Guide | ERC 211 DKRCE.PI.RL0.F7.ML...
  • Seite 11 - When the keypad is locked any button press shows “LoC” in the display. - Press UP and DOWN buttons simultaneously for 3 seconds to unlock the keyboard. “unl” is displayed for 3 seconds. DKRCE.PI.RL0.F7.ML Installation Guide | ERC 211 | 11...
  • Seite 12 +/-1 K above 25 °C Type of action 1B (relay) DO1 Compressor relay: 16 A, 16 (16) A, EN 60730-1 Output 10 FLA/60 LRA at 230 V, UL60730-1 16 FLA/72 LRA at 115 V, UL60730-1 | 12 Installation Guide | ERC 211 DKRCE.PI.RL0.F7.ML...
  • Seite 13 UL recognition (US & Canada) (UL 60730-1) ENEC (EN 60730-1) CE (LVD & EMC Directive) Approvals EAC (GHOST) ROHS2.0 HACCP temperature monitoring in compliance with EN134785 Class I, when used with AKS 12 sensor DKRCE.PI.RL0.F7.ML Installation Guide | ERC 211 | 13...
  • Seite 14 App 4 Heating Heating Thermostat (20 – 60 °C) None None Cooling/ App 5 None (no preset application) with simplified parameter list Heating APP 1/2/3 APP 4 Sair Sair V AC V AC | 14 Installation Guide | ERC 211 DKRCE.PI.RL0.F7.ML...
  • Seite 15 9 - Parameter List App. 0 Parameter name - ERC 211 Code Unit App. 1 App. 2 App. 3 App. 4 App. 5 (Def.) Configuration Main switch -1=service, 0=OFF, 1=ON Predefined applications AP0, AP1, AP2, AP3, AP4, AP5 Sensor type selection...
  • Seite 16 App. 0 Parameter name - ERC 211 Code Unit App. 1 App. 2 App. 3 App. 4 App. 5 (Def.) High temperature alarm limit -100.0 200.0 (Cabinet/room) Low temperature alarm limit -100.0 200.0 -30.0 -30.0 DI1 delay (time delay for selected DI1 function)
  • Seite 17 App. 0 Parameter name - ERC 211 Code Unit App. 1 App. 2 App. 3 App. 4 App. 5 (Def.) Others Delay of outputs at startup DI1 configuration oFF=not used, Sdc=status display output, doo=door alarm with resumption, doA=door alarm without resumption,...
  • Seite 18 App. 0 Parameter name - ERC 211 Code Unit App. 1 App. 2 App. 3 App. 4 App. 5 (Def.) Polarity DI1 input polarity nc=normally closed, no=normally open Keyboard lock enable Readouts Controller status S0=cooling ON/Heating ON, S2=wait for compressor ON time to elapse,...
  • Seite 19 App. 0 Parameter name - ERC 211 Code Unit App. 1 App. 2 App. 3 App. 4 App. 5 (Def.) Alarm status Sair air temperature sensor error High temperature alarm Low temperature alarm High voltage alarm Low voltage alarm Condenser alarm...
  • Seite 20 002566703-0001 Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without subsequent changes being necessary in specifications already agreed.
  • Seite 21 Notes DKRCE.PI.RL0.F7.ML Installation Guide | ERC 211 | 21...
  • Seite 22 L’ERC 211 est un système intégré de contrôle de la réfrigération intelligent et multifonction, avec gestion de la température et du dégivrage, disponible avec 1 relais. Ce régulateur sert de commande assujettie à la température de fonctionnement, qui convient aux applications de réfrigération et de chauffage.
  • Seite 23 Pression prolongée : DÉGIVRAGE Pression prolongée : MENU Icônes de l’afficheur Mode nuit Ventilateur en Dégivrage (économies d’énergie) fonctionnement Compresseur en fonctionnement Alarme active Unité (°C ou °F) (clignote en mode diminution) DKRCE.PI.RL0.F7.ML Installation Guide | ERC 211 | 23...
  • Seite 24 Applications à moyenne température (2 – 6 °C), avec arrêt de dégivrage naturel par la température de l’air App 4 Thermostat de chauffage simple (20 – 60 °C) App 5 Aucun (pas de présélection) avec la liste des paramètres simplifiés | 24 Installation Guide | ERC 211 DKRCE.PI.RL0.F7.ML...
  • Seite 25 Sélectionner le type de sonde en appuyant sur HAUT/BAS (n5=NTC 5 K, n10=NTC 10 K, Ptc=PTC, Pt1=Pt1000) et appuyer sur SET pour confirmer. REMARQUE: toutes les sondes doivent être du même type. DKRCE.PI.RL0.F7.ML Installation Guide | ERC 211 | 25...
  • Seite 26 4 - Structure de menus | 26 Installation Guide | ERC 211 DKRCE.PI.RL0.F7.ML...
  • Seite 27 - Appuyer sur HAUT/BAS pour sélectionner une application (AP0=pas d’application sélectionnée). - Appuyer sur SET pour confirmer, “ o61 “ s’affiche. Continuer à régler les paramètres suivants (type de sonde “ o06 “) dans le menu “ cfg “. DKRCE.PI.RL0.F7.ML Installation Guide | ERC 211 | 27...
  • Seite 28 Lancer un dégivrage manuel DEFROST (Dégivrage) : appuyer pendant 3 secondes pour lancer un dégivrage. DEFROST : appuyer pendant 3 secondes pour arrêter le dégivrage manuel. L’icône DEFROST s’affiche pendant le dégivrage. | 28 Installation Guide | ERC 211 DKRCE.PI.RL0.F7.ML...
  • Seite 29 - Lorsque le clavier est verrouillé, la pression sur une touche entraîne l’affichage de « LoC ». - Appuyer simultanément sur la touche HAUT et BAS pendant 3 secondes pour déverrouiller le clavier. « unl » s’affiche pendant 3 secondes. DKRCE.PI.RL0.F7.ML Installation Guide | ERC 211 | 29...
  • Seite 30 Type d’action 1B (relais) Relais du compresseur DO1 16 A, 16 (16) A, EN 60730-1 Sortie 10 FLA/ 60 LRA à 230 V, UL60730-1 16 FLA/ 72 LRA à 115 V, UL60730-1 | 30 Installation Guide | ERC 211 DKRCE.PI.RL0.F7.ML...
  • Seite 31 UL reconaissance (US & Canada) (UL 60730-1) ENEC (EN 60730-1) CE (LVD & EMC Directive) Homologations EAC (GHOST) ROHS2.0 Surveillance de température HACCP en conformité avec EN134785 Classe I, Lorsque l’on utilise des sondes AKS 12 DKRCE.PI.RL0.F7.ML Installation Guide | ERC 211 | 31...
  • Seite 32 Thermostat de chauffage simple (20 – 60 °C) Aucun Aucun Refrodis./ App 5 Aucun (pas de présélection) avec la liste des paramètres simplifiés Chauff. APP 1/2/3 APP 4 Sair Sair V AC V AC | 32 Installation Guide | ERC 211 DKRCE.PI.RL0.F7.ML...
  • Seite 33 9 -Liste des paramètres App. 0 Nom du paramètre - ERC 211 Code Min. Max. Unité App. 1 App. 2 App. 3 App. 4 App. 5 (Def.) Configuration Sectionneur principal -1=entretien, 0=arrêt, 1=marche Applications prédéfinies AP0, AP1, AP2, AP3, AP4, AP5 Sélection du type de sonde...
  • Seite 34 App. 0 Nom du paramètre - ERC 211 Code Min. Max. Unité App. 1 App. 2 App. 3 App. 4 App. 5 (Def.) Alarme Temporisation de l’alarme de température pendant des conditions normales Temporisation de l’alarme de température pendant diminution/démarrage/dégivrage Seuil d’alarme de température élevée...
  • Seite 35 App. 0 Nom du paramètre - ERC 211 Code Min. Max. Unité App. 1 App. 2 App. 3 App. 4 App. 5 (Def.) Compresseur Durée minimum de marche du compresseur Durée de mise hors tension minimum du compresseur Temporisation d’arrêt du compresseur à...
  • Seite 36 App. 0 Nom du paramètre - ERC 211 Code Min. Max. Unité App. 1 App. 2 App. 3 App. 4 App. 5 (Def.) Applications prédéfinies Enregistrer les réglages par défaut AVERTISSEMENT : les réglages d’usine antérieurs sont écrasés Affichage au dégivrage Air=température réelle de l’air,...
  • Seite 37 App. 0 Nom du paramètre - ERC 211 Code Min. Max. Unité App. 1 App. 2 App. 3 App. 4 App. 5 (Def.) Température du condenseur (Sc) -100.0 200.0 État du relais du compresseur Relevé de la version du micrologiciel État d’alarme...
  • Seite 38 Danfoss n’assume aucune responsabilité quant aux éventuelles erreurs présentes dans les catalogues, brochures ou autres documentations écrites. Danfoss se réserve le droit de modifier ses produits sans préavis. Cela vaut également pour les produits déjà commandés pour autant que ces modifications se fassent sans changements ultérieurs des spécifications convenues.
  • Seite 39 Remarque DKRCE.PI.RL0.F7.ML Installation Guide | ERC 211 | 39...
  • Seite 40 El ERC 211 es un controlador de refrigeración integrado multifuncional e inteligente con gestión de temperatura y de desescarche, disponible con 1 relé. Este controlador se utiliza para el control de la detección de la temperatura de funcionamiento, por lo que resulta apto para aplicaciones de refrigeración y calefacción.
  • Seite 41 Pulsación prolongada: DESESCARCHE Pulsación prolongada: MENÚ Iconos de la pantalla Modo nocturno Ventilador en funcionamiento Desescarche (ahorro energético) Compresor en funcionamiento Alarma activa Unidad (°C o °F) (parpadea en el modo de vaciado) DKRCE.PI.RL0.F7.ML Installation Guide | ERC 211 | 41...
  • Seite 42 Termostato de la calefacción simple (20 – 60 °C). Estas aplicaciones no cambian ningún valor, sólo reducen App 4 la cantidad de parámetros que se desea modificar Estas aplicaciones no cambian ningún valor, sólo reducen la cantidad de parámetros que se desea App 5 modificar | 42 Installation Guide | ERC 211 DKRCE.PI.RL0.F7.ML...
  • Seite 43 La pantalla mostrará el valor predeterminado de forma intermitente (por ejemplo, “n10”). Elija el tipo de sensor pulsando ARRIBA/ABAJO (n5=NTC 5 K, n10=NTC 10 K, Ptc=PTC, Pt1=Pt1000); pulse SET para confirmar. NOTA: Todos los sensores deben ser del mismo tipo DKRCE.PI.RL0.F7.ML Installation Guide | ERC 211 | 43...
  • Seite 44 4 - Estructura del menú | 44 Installation Guide | ERC 211 DKRCE.PI.RL0.F7.ML...
  • Seite 45 - Pulse SET para acceder al parámetro “o61”. - Pulse ARRIBA/ABAJO para seleccionar una aplicación (AP0=ninguna aplicación seleccionada). - Pulse SET para confirmar; la pantalla mostrará “o61”. Continúe configurando el tipo de sens (“o06”) en el menú “cFg”. DKRCE.PI.RL0.F7.ML Installation Guide | ERC 211 | 45...
  • Seite 46 Inicio de un desescarche manual DESESCARCHE: mantener pulsado durante 3 segundos para iniciar el desescarche. DESESCARCHE: mantener pulsado durante 3 segundos para detener el desescarche manual. La pantalla mostrará el icono de DESESCARCHE durante el desescarche. | 46 Installation Guide | ERC 211 DKRCE.PI.RL0.F7.ML...
  • Seite 47 (si P76 = yES). - Cuando el teclado está bloqueado, la pantalla muestra “LoC” al pulsar cualquier botón. - Cuando el teclado está bloqueado, la pantalla muestra “LoC” al pulsar cualquier botón. DKRCE.PI.RL0.F7.ML Installation Guide | ERC 211 | 47...
  • Seite 48 Tipo de acción 1B (relé) Relé de compresor DO1: 16 A, 16 (16) A (EN 60730-1) Salida 10 FLA/60 LRA at 230 V (UL 60730-1) 16 FLA/72 LRA at 115 V (UL 60730-1) | 48 Installation Guide | ERC 211 DKRCE.PI.RL0.F7.ML...
  • Seite 49 UL reconocimiento (US & Canada) (UL 60730-1) ENEC (EN 60730-1) CE (LVD & EMC Directive) Homologaciones EAC (GHOST) ROHS2.0 Monitorización de temperatura HACCP en conformidad con EN134785 Clase I, Cuando se utiliza con un sensor AKS 12 DKRCE.PI.RL0.F7.ML Installation Guide | ERC 211 | 49...
  • Seite 50 Ninguno Ninguno Enfriam./ Estas aplicaciones no cambian ningún valor, sólo reducen la Apl. 5 Calefac cantidad de parámetros que se desea modificar APP 1/2/3 APP 4 Sair Sair V AC V AC | 50 Installation Guide | ERC 211 DKRCE.PI.RL0.F7.ML...
  • Seite 51 (desviación de la temperatura en el modo -50.0 50.0 nocturno) Desviación de temperatura del desplazamiento de referencia del -50.0 50.0 termostato Tiempo de vaciado Límite de temperatura de vaciado -100.0 200.0 Nota: Los parámetros ocultos se muestran atenuados. DKRCE.PI.RL0.F7.ML Installation Guide | ERC 211 | 51...
  • Seite 52 Retardo del desescarche al encender 240.0 (o con señal DI) Retardo de goteo Configuración del sensor de parada del desescarche non=tiempo, Air=Sair (temperatura del aire) Nota: Los parámetros ocultos se muestran atenuados. | 52 Installation Guide | ERC 211 DKRCE.PI.RL0.F7.ML...
  • Seite 53 5 K, n10=NTC 10 K, Ptc=PTC, Pt1=Pt1000 Frío/Calor rE=de refrigeración (enfriamiento), Ht=calefacción Resolución de la pantalla 0.1=intervalos de 0.1 °C, 0.5=intervalos de 0.5 °C, 1.0=ntervalos de 1.0 °C Nota: Los parámetros ocultos se muestran atenuados. DKRCE.PI.RL0.F7.ML Installation Guide | ERC 211 | 53...
  • Seite 54 S17=compuerta abierta (entrada digital DI), S20=refrigeración de emergencia, S25=control manual de las salidas, S30=ciclo continuo/vaciado, S32=retardo de las salidas al encender Nota: Los parámetros ocultos se muestran atenuados. | 54 Installation Guide | ERC 211 DKRCE.PI.RL0.F7.ML...
  • Seite 55 Alarma de baja temperatura Alarma de alta tensión Alarma de baja tensión Alarma del condensador Alarma de compuerta Alarma en espera Alarma externa de entrada digital DI Nota: Los parámetros ocultos se muestran atenuados. DKRCE.PI.RL0.F7.ML Installation Guide | ERC 211 | 55...
  • Seite 56 Todas las marcas registradas de este material son propiedad de sus respectivos titulares. Danfoss y el logotipo de Danfoss son marcas registradas de Danfoss A/S. Todos los derechos reservados.
  • Seite 57 Notas DKRCE.PI.RL0.F7.ML Installation Guide | ERC 211 | 57...
  • Seite 58 ERC 211 — это интеллектуальный многофункциональный встраиваемый контроллер системы охлаждения с функциями управления температурой и оттаиванием, оснащенный одним реле. Данное устройство предназначено для контроля рабочей температуры и подходит для применения в системах охлаждения и теплоснабжения. Встраиваемый контроллер разработан для удовлетворения современных требований в области...
  • Seite 59 Нажмите и удерживайте: DEFROST (ОТТАИВАНИЕ) Нажмите и удерживайте: MENU (МЕНЮ) Значки дисплея Ночной режим (экономия энергии) Вентилятор работает Оттаивание Компрессор работает Единица измерения Активный сигнал тревоги (мигает в режиме захолаживания) (°C или °F) DKRCE.PI.RL0.F7.ML Installation Guide | ERC 211 | 59...
  • Seite 60 Среднетемпературная установка (2 – 6 °C), с естественной оттайкой, остановка по времени Прил. 3 Среднетемпературная установка (2 – 6 °C), с естественной оттайкой, остановка по температуре воздуха Прил. 4 Нагревательный термостат (20 – 60 °C) Прил. 5 Нет (приложение отсутствует) упрощенного списка параметров | 60 Installation Guide | ERC 211 DKRCE.PI.RL0.F7.ML...
  • Seite 61 На дисплее отображается значение по умолчанию (например, мигает “n10”) Выберите тип датчика, нажав кнопку UP/DOWN (ВВЕРХ/ВНИЗ) (n5=NTC 5 K, n10=NTC 10 K, Ptc=PTC, Pt1=Pt1000), и нажмите SET (НАСТРОЙКА) для подтверждения. ПРИМЕЧАНИЕ: все датчики должны быть одного и того же типа. DKRCE.PI.RL0.F7.ML Installation Guide | ERC 211 | 61...
  • Seite 62 4 - Структура меню | 62 Installation Guide | ERC 211 DKRCE.PI.RL0.F7.ML...
  • Seite 63 - нажмите UP/DOWN (ВВЕРХ/ВНИЗ) для выбора приложения (AP0=приложение не выбрано); - нажмите SET (НАСТРОЙКА) для подтверждения, на дисплее отображается “o61”. Продолжите, чтобы выполнить настройку следующих параметров (тип датчика “o06” ) в меню “cFg”. DKRCE.PI.RL0.F7.ML Installation Guide | ERC 211 | 63...
  • Seite 64 SET (НАСТРОЙКА): сохраните заданное значение температуры. DEFROST (ОТТАИВАНИЕ): нажмите на 3 секунды для инициирования оттаивания. DEFROST (ОТТАИВАНИЕ): нажмите на 3 секунды для прекращения ручного оттаивания. Во время оттаивания отображается значок DEFROST (ОТТАИВАНИЕ). | 64 Installation Guide | ERC 211 DKRCE.PI.RL0.F7.ML...
  • Seite 65 - Когда клавиатура заблокирована, при нажатии на любую кнопку на дисплее отображается "LoC". - Нажмите одновременно кнопки UP (ВВЕРХ) и DOWN (ВНИЗ) на 3 секунды для разблокирования клавиатуры. "unl" отображается в течение 3 секунд. DKRCE.PI.RL0.F7.ML Installation Guide | ERC 211 | 65...
  • Seite 66 от -40 до 105 °C (от -40 до 221 °F) Точность Точность регулятора: +/-1 K ниже -35 °C, +/- 0.5 K от -35 до 25 °C, +/-1 K выше 25 °C Тип воздействия 1B (реле) | 66 Installation Guide | ERC 211 DKRCE.PI.RL0.F7.ML...
  • Seite 67 UL признание (US & Canada) (UL 60730-1) ENEC (EN 60730-1) CE (LVD & EMC Directive) Сертификация EAC (GHOST) ROHS2.0 Температурный мониторинг HACCP в соответствии с EN134785 Class I, когда используется датчик AKS 12 DKRCE.PI.RL0.F7.ML Installation Guide | ERC 211 | 67...
  • Seite 68 Прил. 4 отопление Нагревательный термостат (20 – 60 °C) Ни один Ни один охлаждение/ Нет (приложение отсутствует) упрощенного списка Прил. 5 отопление параметров APP 1/2/3 APP 4 Sair Sair V AC V AC | 68 Installation Guide | ERC 211 DKRCE.PI.RL0.F7.ML...
  • Seite 69 9 - Список параметров Ед. изм. Прил. 0 Имя параметра - ERC 211 Код Мин. Макс. Прил. 1 Прил. 2 Прил. 3 Прил. 4 Прил. 5 Опред. Конфигурация Главный выключатель -1=работа, 0=ВЫКЛ, 1=ВКЛ Предопределенные приложения AP0, AP1, AP2, AP3, AP4 Выбор...
  • Seite 70 Ед. изм. Прил. 0 Имя параметра - ERC 211 Код Мин. Макс. Прил. 1 Прил. 2 Прил. 3 Прил. 4 Прил. 5 Опред. Тревожная сигнализация Задержка срабатывания аварийного сигнала мин температуры в нормальном режиме Задержка срабатывания аварийного сигнала температуры в режиме ускоренного...
  • Seite 71 Ед. изм. Прил. 0 Имя параметра - ERC 211 Код Мин. Макс. Прил. 1 Прил. 2 Прил. 3 Прил. 4 Прил. 5 Опред. Настройка датчика прекращения оттаивания non=время, Air=Sair (температура воздуха) Общая длительность работы компрессора часы для начала оттаивания 0 =ВЫКЛ...
  • Seite 72 Ед. изм. Прил. 0 Имя параметра - ERC 211 Код Мин. Макс. Прил. 1 Прил. 2 Прил. 3 Прил. 4 Прил. 5 Опред. Разрешение дисплея 0.1=с шагом 0.1 °C, 0,5=с шагом 0.5 °C, 1.0=с шагом 1.0 °C Счетчик реле 1 (1 счетчик=100 циклов...
  • Seite 73 Ед. изм. Прил. 0 Имя параметра - ERC 211 Код Мин. Макс. Прил. 1 Прил. 2 Прил. 3 Прил. 4 Прил. 5 Опред. Показания Состояние контроллера S0=охлаждение включено/нагревание включено, S2=ожидание, пока пройдет время включения компрессора, S3=ожидание, пока пройдет время отключения...
  • Seite 74 Ед. изм. Прил. 0 Имя параметра - ERC 211 Код Мин. Макс. Прил. 1 Прил. 2 Прил. 3 Прил. 4 Прил. 5 Опред. Состояние тревожной сигнализации Ошибка датчика температуры воздуха Sair Тревожная сигнализация повышенной температуры Тревожная сигнализация низкой температуры Тревожная сигнализация высокого...
  • Seite 75 Регистрация промышленного образца ЕС 002566703-0001 Компания Danfoss не несет ответственности за возможные ошибки в каталогах, брошюрах и других печатных материалах. Компания Danfoss оставляет за собой право изменять характеристики изделий без предварительного уведомления. Это положение также распространяется на уже заказанные продукты, но при условии, что внесение таких изменений...
  • Seite 76 O ERC 211 é um controlador de refrigeração integrado inteligente e universal com gerenciamento de temperatura e degelo, disponível com 1 relé. Este controlador foi elaborado para o controle da medição de temperatura de operação, adequado em aplicações de refrigeração e aquecimento.
  • Seite 77 SETPOINT DE TEMPERATURA/OK Pressionar prolongadamente: DEGELO Pressionar prolongadamente: MENU Ícones do visor Modo noturno Ventilador em Degelo (Economia de energia) funcionamento Compressor em funcionamento Alarme ativo Unidade (°C ou °F) Flashes no modo pull-down DKRCE.PI.RL0.F7.ML Installation Guide | ERC 211 | 77...
  • Seite 78 Temperatura média (2 – 6 °C), com degelo natural parada determinada pela temperatura do ar Aplic 4 Termostato de Aquecimento (20 – 60 °C) Aplic 5 Não há aplicação predefinida com uma lista simplificada de parâmetros | 78 Installation Guide | ERC 211 DKRCE.PI.RL0.F7.ML...
  • Seite 79 O visor mostra o valor padrão (por ex., “n10” intermitente). Escolha o tipo de sensor apertando PARA CIMA/PARA BAIXO (n5=NTC 5 K, n10=NTC 10 K, Ptc=PTC, Pt1=Pt1000) e pressione SET para confirmar. NOTA: Todos os sensores devem ser do mesmo tipo. DKRCE.PI.RL0.F7.ML Installation Guide | ERC 211 | 79...
  • Seite 80 4 - Estrutura do menu | 80 Installation Guide | ERC 211 DKRCE.PI.RL0.F7.ML...
  • Seite 81 - Pressione PARA CIMA/PARA BAIXO para selecionar uma aplicação (AP0= não existe uma aplicação selecionada). - Pressione SET para confirmar, aparece “o61” na tela. Continue definindo os parâmetros seguintes (“tipo de sensor o06”) no menu “cFg”. DKRCE.PI.RL0.F7.ML Installation Guide | ERC 211 | 81...
  • Seite 82 SET: salva o setpoint de temperatura. Iniciar degelo manual DEGELO: pressione por 3 segundos para iniciar degelo. DEGELO: pressione por 3 segundos para parar o degelo manual. O ícone de DEGELO aparece durante o degelo. | 82 Installation Guide | ERC 211 DKRCE.PI.RL0.F7.ML...
  • Seite 83 - Enquanto o teclado estiver bloqueado, qualquer botão pressionado mostrará <<LoC>> no visor. - Pressione simultaneamente os botões PARA CIMA e PARA BAIXO por 3 segundos para desbloquear o teclado. O visor mostra <<unl>> por 3 segundos. DKRCE.PI.RL0.F7.ML Installation Guide | ERC 211 | 83...
  • Seite 84 -40 a 105 °C (-40 a 221 °F) Precisão Precisão do controlador: +/- 1 K abaixo de -35 °C, +/- 0.5 K entre -35 e 25 °C, +/- 1 K acima de 25 °C Tipo de ação 1B (relé) | 84 Installation Guide | ERC 211 DKRCE.PI.RL0.F7.ML...
  • Seite 85 Homologação UL (US & Canada) (UL 60730-1) ENEC (EN 60730-1) CE (LVD & EMC Directive) Aprovações EAC (GHOST) ROHS2.0 Monitoramento de temperatura HACCP de acordo com a norma EN134785 Classe I, quando utilizado com o sensor AKS12 DKRCE.PI.RL0.F7.ML Installation Guide | ERC 211 | 85...
  • Seite 86 (20 – 60 °C) Nenhum Nenhum ção 4 Aplica- Refrigeração/ Não há aplicação predefinida com uma lista simplificada de ção 5 Aquecimento parâmetros APP 1/2/3 APP 4 Sair Sair V AC V AC | 86 Installation Guide | ERC 211 DKRCE.PI.RL0.F7.ML...
  • Seite 87 9 - Lista de parâmetros Uni- App. 0 Nome do parâmetro - ERC 211 Código Mín. Máx. App. 1 App. 2 App. 3 App. 4 App. 5 dade (Def.) Configuração Interrutor principal -1=serviço, 0=DESLIGADO, 1=LIGADO Aplicações pré-definidas AP0, AP1, AP2, AP3, AP4, AP5 Seleção do tipo de sensor...
  • Seite 88 Uni- App. 0 Nome do parâmetro - ERC 211 Código Mín. Máx. App. 1 App. 2 App. 3 App. 4 App. 5 dade (Def.) Alarme Delay para o alarme de temperatura em condições normais Delay para o alarme de temperatura...
  • Seite 89 Uni- App. 0 Nome do parâmetro - ERC 211 Código Mín. Máx. App. 1 App. 2 App. 3 App. 4 App. 5 dade (Def.) Tempo de funcionamento do compressor para iniciar o degelo horas 0=OFF Delay para degelo após pull-down...
  • Seite 90 Uni- App. 0 Nome do parâmetro - ERC 211 Código Mín. Máx. App. 1 App. 2 App. 3 App. 4 App. 5 dade (Def.) Aplicações pré-definidas Salvar pré-definições AVISO: As definições de fábrica anteriores serão substituídas Display no degelo Air=temperatura de ar real, FrE=temperatura congelada, -d-=”-d-”...
  • Seite 91 Uni- App. 0 Nome do parâmetro - ERC 211 Código Mín. Máx. App. 1 App. 2 App. 3 App. 4 App. 5 dade (Def.) Temperatura do condensador (Sc) -100.0 200.0 Status do relé do compressor Leitura da versão de firmware...
  • Seite 92 Registo de design na UE 002566703-0001 A Danfoss não se responsabiliza por possíveis erros em catálogos, brochuras ou outros materiais impressos. A Danfoss se reserva o direito de alterar os seus produtos sem aviso prévio. Isto se aplica a produtos já encomendados desde que essas alterações não afetem especificações já...
  • Seite 93 Notas DKRCE.PI.RL0.F7.ML Installation Guide | ERC 211 | 93...
  • Seite 94 ERC 211 to inteligentny, uniwersalny, zintegrowany sterownik urządzeń chłodniczych z regulacją temperatury i odszraniania, dostępny w wersji z 1 przekaźnikiem. Sterownik ten służy do regulacji pomiaru temperatury pracy i nadaje się do zastosowań związanych z chłodzeniem i ogrzewaniem. Zintegrowany sterownik spełnia wymagania nowoczesnych komercyjnych urządzeń chłodniczych.
  • Seite 95 Krótkie naciśnięcie: Krótkie naciśnięcie: DÓŁ NASTAWA TEMPERATURY/OK Długie naciśnięcie: ODTAJANIE Długie naciśnięcie: MENU Ikony wyświetlacza Tryb nocny Wentylator pracuje Odtajanie (energooszczędny) Sprężarka pracuje Aktywny alarm Jednostka (°C lub °F) Miga w trybie wychładzania DKRCE.PI.RL0.F7.ML Installation Guide | ERC 211 | 95...
  • Seite 96 Temperatura czynnika (2 – 6 °C), z naturalnym odtajaniem zatrzymywanym po uzyskaniu okreslonej temperatury Aplikacja 4 Termostat ogrzewania (20 – 60 °C) Aplikacja 5 Brak (nie ustawiona aplikacja) z uproszczonej listy parametrów | 96 Installation Guide | ERC 211 DKRCE.PI.RL0.F7.ML...
  • Seite 97 Wybierz typ czujnika przyciskami GÓRA/DÓŁ (N5 = NTC 5K, n10 = NTC 10K, Ptc = PTC, Pt1 = Pt1000) i naciśnij przycisk SET (Ustawianie), aby potwierdzić. UWAGA: Wszystkie czujniki muszą być tego samego typu. DKRCE.PI.RL0.F7.ML Installation Guide | ERC 211 | 97...
  • Seite 98 4. Struktura menu | 98 Installation Guide | ERC 211 DKRCE.PI.RL0.F7.ML...
  • Seite 99 - Naciskaj przyciski GÓRA/DÓŁ, aby wybrać aplikację (AP0 = nie wybrano aplikacji). - Naciśnij przycisk SET (Ustawianie), aby potwierdzić — wyświetlany jest parametr “o61”. Kontynuuj ustawianie następnych parametrów (typ czujnika “o06” ) w menu “cFg”. DKRCE.PI.RL0.F7.ML Installation Guide | ERC 211 | 99...
  • Seite 100 Inicjowanie recznego odtajania ODTAJANIE: nacisnij przycisk i przytrzymaj go przez 3 sekundy, aby rozpoczac odtajanie ODTAJANIE: nacisnij przycisk i przytrzymaj go przez 3 sekundy, aby zatrzymac reczne odtajanie. Podczas odtajania wyswietlana jest ikona ODTAJANIA. | 100 Installation Guide | ERC 211 DKRCE.PI.RL0.F7.ML...
  • Seite 101 - Gdy klawiatura jest zablokowana, nacisniecie dowolnego przycisku powoduje wyswietlenie na wyswietlaczu komunikatu „LOC”. - Aby odblokowac klawiature, nacisnij jednoczesnie przyciski GÓRA i DÓŁ i przytrzymaj je przez 3 sekundy. Przez 3 sekundy wyswietlany jest komunikat „unl”. DKRCE.PI.RL0.F7.ML Installation Guide | ERC 211 | 101...
  • Seite 102 Od -40 do 105 °C (od -40 do 221°F) Dokładność Dokładność sterownika: +/-1 K poniżej -35 °C, +/-0.5 K od -35 do 25 °C, +/-1 K powyżej 25 °C Rodzaj działania 1B (przekaźnik) | 102 Installation Guide | ERC 211 DKRCE.PI.RL0.F7.ML...
  • Seite 103 UL Dopuszczenia (US & Canada) (UL 60730-1) ENEC (EN 60730-1) CE (LVD & EMC Directive) Certyfikaty EAC (GHOST) ROHS2.0 HACCP monitoring temperatury zgodny z EN134785 klasa I, gdy zastosowany z czujnikiem AKS 12 DKRCE.PI.RL0.F7.ML Installation Guide | ERC 211 | 103...
  • Seite 104 Termostat ogrzewania (20 – 60 °C) (20 – 60 °C) żaden żaden ogrzewanie/ Aplik. 5 Brak (nie ustawiona aplikacja) z uproszczonej listy parametrów chłodzenie APP 1/2/3 APP 4 Sair Sair V AC V AC | 104 Installation Guide | ERC 211 DKRCE.PI.RL0.F7.ML...
  • Seite 105 -1=serwis, 0=WYŁ., 1=WŁ. Nocne obniżenie temperatury (przesunięcie nastawy temperatury w -50.0 50.0 trybie nocnym) Przesunięcie temperatury -50.0 50.0 odniesienia termostatu Czas trwania wychładzania -100.0 200.0 Graniczna temperatura wychładzania Uwaga: ukryte parametry są wyszarzone DKRCE.PI.RL0.F7.ML Installation Guide | ERC 211 | 105...
  • Seite 106 Opóźnienie ze względu na ociekanie Konfiguracja czujnika końca odtajania non=według czasu, Air=czujnik Sair (czujnik przestrzeni chłodzonej) Sumaryczny czas pracy sprężarki do godz. rozpoczęcia odtajania, 0=WYŁ. Opóźnienie odtajania po wychładzaniu 0=WYŁ. Uwaga: ukryte parametry są wyszarzone | 106 Installation Guide | ERC 211 DKRCE.PI.RL0.F7.ML...
  • Seite 107 Rozdzielczość wyświetlania temperatury 0.1=z dokładnością do 0,1°C, 0.5=z dokładno ścią do 0,5°C, 1.0=z dokładnością do 1.0°C Licznik przekaźnika 1 (zwiększenie wskazania o 1=100 cykli pracy) Predefiniowane aplikacje Uwaga: ukryte parametry są wyszarzone DKRCE.PI.RL0.F7.ML Installation Guide | ERC 211 | 107...
  • Seite 108 S14=stan odtajania, S15=stan opóźnienia włączenia wentylatora po odtajaniu, S17=otwarte drzwi (wejście DI), S20=chłodzenie awaryjne, S25=ręczne sterowanie wyjściami, S30=praca ciągła sprężarki/wychładzanie, S32=opóźnienie załaczenia przekaźników (wyjść) po włączeniu zasilania Uwaga: ukryte parametry są wyszarzone | 108 Installation Guide | ERC 211 DKRCE.PI.RL0.F7.ML...
  • Seite 109 Błąd czujnika temperatury powietrza Sair Alarm wysokiej temperatury Alarm niskiej temperatury Alarm wysokiego napięcia Alarm niskiego napięcia Alarm wysokiej temperatury skraplacza Alarm drzwi Alarm stanu gotowości Alarm zewnętrzny z wejścia DI Uwaga: ukryte parametry są wyszarzone DKRCE.PI.RL0.F7.ML Installation Guide | ERC 211 | 109...
  • Seite 110 Numer rejestracji konstrukcji w UE 002566703-0001 Firma Danfoss nie ponosi żadnej odpowiedzialności za potencjalne błędy w katalogach, broszurach i innych wydrukowanych materiałach. Firma Danfoss zastrzega sobie prawo do dokonywania zmian w swoich produktach bez powiadomienia. Dotyczy to również produktów już zamówionych, z zastrzeżeniem, że takie zmiany można wprowadzić bez konieczności zmieniania już...
  • Seite 111 Uwagi DKRCE.PI.RL0.F7.ML Installation Guide | ERC 211 | 111...
  • Seite 112 L’ERC 211 è un regolatore di refrigerazione integrato intelligente e multiuso con gestione della temperatura e dello sbrinamento, disponibile con 1 relè. Questo regolatore viene utilizzato per il controllo sensibile della temperatura d’esercizio ed è adatto alle applicazioni di refrigerazione e riscaldamento.
  • Seite 113 SETPOINT TEMPERATURA/OK Premere senza rilasciare: SBRINAMENTO Premere senza rilasciare: MENU Icone display Modalità notturna Ventola in funzione Sbrinamento (risparmio energetico) Compressore in funzione Allarme attivo Unità (°C o °F) Lampeggia in modalità pull-down DKRCE.PI.RL0.F7.ML Installation Guide | ERC 211 | 113...
  • Seite 114 Temperatura media (2 – 6 °C), con arresto sbrinamento naturale (in base alla temperatura) App 4 Termostato riscaldamento (20 – 60 °C) App 5 Nessuna (nessuna applicazione preimpostata) con elenco parametri semplificato | 114 Installation Guide | ERC 211 DKRCE.PI.RL0.F7.ML...
  • Seite 115 Il display visualizza il valore di default (per es. “n10”, lampeggiante). Scegliere il tipo di sensore premendo SU/GIÙ (n5=NTC 5 K, n10=NTC 10 K, Ptc=PTC, Pt1=Pt1000) e premere SET per confermare. NOTA: tutti i sensori devono essere dello stesso tipo. DKRCE.PI.RL0.F7.ML Installation Guide | ERC 211 | 115...
  • Seite 116 4 - Struttura del menu | 116 Installation Guide | ERC 211 DKRCE.PI.RL0.F7.ML...
  • Seite 117 - Premere SET per accedere al parametro “o61”. - Premere SU/GIÙ per selezionare un’applicazione (AP0= nessuna applicazione). - Premere SET per confermare; “o61” viene visualizzato. Continuare a impostare i parametri successivi (tipo di sensore “o06”) nel menu “cFg”. DKRCE.PI.RL0.F7.ML Installation Guide | ERC 211 | 117...
  • Seite 118 SET: salva il setpoint della temperatura. Avvio di uno sbrinamento manuale SBRINAMENTO: premere per 3 secondi per avviare lo sbrinamento. SBRINAMENTO: premere per 3 secondi per arrestare lo sbrinamento manuale. L'icona SBRINAMENTO viene visualizzata durante lo sbrinamento. | 118 Installation Guide | ERC 211 DKRCE.PI.RL0.F7.ML...
  • Seite 119 - Quando la tastiera è bloccata, qualsiasi selezione di un tasto visualizza “LoC” sul display. - Premere simultaneamente i pulsanti SU e GIÙ per 3 secondi per sbloccare la tastiera. “unl” viene visualizzato per 3 secondi. DKRCE.PI.RL0.F7.ML Installation Guide | ERC 211 | 119...
  • Seite 120 Tipo di azione 1B (relè) Relè compressore DO1: 16 A, 16 (16) A, EN 60730-1 Uscita 10 FLA / 60 LRA a 230 V, UL60730-1 16 FLA / 72 LRA a 115 V, UL60730-1 | 120 Installation Guide | ERC 211 DKRCE.PI.RL0.F7.ML...
  • Seite 121 Riconoscimento UL (USA e Canada) (UL 60730-1) ENEC (EN 60730-1) EC (Direttiva LVD e EMC) Approvazioni EAC (GHOST) ROHS2.0 Monitoraggio della temperatura HACCP in conformità a EN134785 Classe I se utilizzato con sensore AKS 12 DKRCE.PI.RL0.F7.ML Installation Guide | ERC 211 | 121...
  • Seite 122 App 4 Riscaldamento Termostato riscaldamento (20 – 60 °C) Nessuno Nessuno Refrigerazione/ Nessuna (nessuna applicazione preimpostata) App 5 Riscaldamento con elenco parametri semplificato APP 1/2/3 APP 4 Sair Sair V CA V CA | 122 Installation Guide | ERC 211 DKRCE.PI.RL0.F7.ML...
  • Seite 123 9 - Elenco parametri App. 0 Nome parametro - ERC 211 Codice Unità App. 1 App. 2 App. 3 App. 4 App. 5 (Sbr.) Configurazione Interruttore principale -1=servizio, 0=OFF, 1=ON Applicazioni predefinite AP0, AP1, AP2, AP3, AP4, AP5 Selezione tipo sensore...
  • Seite 124 App. 0 Nome parametro - ERC 211 Codice Unità App. 1 App. 2 App. 3 App. 4 App. 5 (Sbr.) Allarme Ritardo allarme temperatura in condizioni normali Ritardo allarme temperatura durante pull-down/avvio/sbrinamento Limite allarme alta temperatura -100.0 200.0 (Cabinet/Ambiente) Limite allarme bassa temperatura -100.0...
  • Seite 125 App. 0 Nome parametro - ERC 211 Codice Unità App. 1 App. 2 App. 3 App. 4 App. 5 (Sbr.) Configurazione del sensore di arresto sbrinamento non=a tempo, Air=Sair (temperatura aria), dEF=S5 (sensore sbrinamento) Tempo accumulato di attivazione compressore per avvio sbrinamento 0=OFF...
  • Seite 126 App. 0 Nome parametro - ERC 211 Codice Unità App. 1 App. 2 App. 3 App. 4 App. 5 (Sbr.) Raffreddamento/Riscaldamento rE=refrigerazione (raffreddamento) Ht=riscaldamento Risoluzione display 0.1=passi di 0,1 °C, 0.5=passi di 0,5 °C, 1.0=passi di 1,0 °C Contatore Relè 1...
  • Seite 127 App. 0 Nome parametro - ERC 211 Codice Unità App. 1 App. 2 App. 3 App. 4 App. 5 (Sbr.) Letture Stato regolatore S0=refrigerazione ON/Riscaldamento ON, S2=attesa fine tempo ON compressore, S3=attesa fine tempo OFF compressore-tempo riavvio, S4=ritardo gocciolamento OFF,...
  • Seite 128 Tutti i marchi in questo materiale sono di proprietà della società. Danfoss e il logotipo Danfoss sono marchi di fabbrica di Danfoss A / S. Tutti i diritti sono riservati. | 128 Installation Guide | ERC 211 DKRCE.PI.RL0.F7.ML...
  • Seite 129 Note DKRCE.PI.RL0.F7.ML Installation Guide | ERC 211 | 129...
  • Seite 130 Der ERC 211 ist ein intelligenter, multifunktionaler integrierter Kühlstellenregler mit Temperatur- und Abtauregelung. Er ist mit 1 Relais erhältlich. Dieser Regler dient der Arbeitstemperaturbereich-Fühlersteuerung und eignet sich für Kälte- und Heizungsanwendungen. Die integrierte Regelung ist so konstruiert, dass sie die heutigen Anforderungen an moderne Gewerbekälteanwendungen erfüllt.
  • Seite 131 Eine Sekunde lang drücken: NACH UNTEN Drücken und gedrückt halten: MENÜ Drücken und gedrückt halten: ABTAUUNG Angezeigte Symbole Nachtmodus Lüfter in Betrieb Abtauung (energiesparend) Verdichter in Betrieb Alarm aktiv Einheit (°C oder °F) Blinkt im Schnellabkühlungsbetrieb DKRCE.PI.RL0.F7.ML Installation Guide | ERC 211 | 131...
  • Seite 132 Medium Temperatur (2 – 6 °C), mit Umluftabtauung Zeitlich begrenzt Anw. 3 Medium Temperatur (2 – 6 °C), mit Umluftabtauung über Fühler begrenzt Anw. 4 Heizthermostat (20 – 60 °C) Anw. 5 Keine (keine voreingestellte Anwendung), mit vereinfachter Parameterliste | 132 Installation Guide | ERC 211 DKRCE.PI.RL0.F7.ML...
  • Seite 133 Den Fühlertyp auswählen, indem die Taste für NACH OBEN/UNTEN (n5 = NTC 5 K, n10 = NTC 10 K, Ptc = PTC, Pt1 = Pt1000) und dann zur Bestätigung SET gedrückt wird. HINWEIS: Alle Fühler müssen vom gleichen Typ sein. DKRCE.PI.RL0.F7.ML Installation Guide | ERC 211 | 133...
  • Seite 134 4 - Menüstruktur | 134 Installation Guide | ERC 211 DKRCE.PI.RL0.F7.ML...
  • Seite 135 - Die Taste für NACH OBEN/UNTEN drücken, um eine Anwendung auszuwählen (AP0 = keine Anwendung ausgewählt). - SET drücken, um zu bestätigen, dass „o61“ angezeigt wird. Im „cFg“-Menü mit der Einstellung der anderen Parameter („o06“ = Fühlertyp) fortfahren. DKRCE.PI.RL0.F7.ML Installation Guide | ERC 211 | 135...
  • Seite 136 Eine manuelle Abtauung auslösen ABTAUUNG: Drei Sekunden lang drücken, um eine manuelle Abtauung auszulösen. ABTAUUNG: Drei Sekunden lang drücken, um die manuelle Abtauung zu beenden Während der Abtauung wird das ABTAUUNGssymbol angezeigt | 136 Installation Guide | ERC 211 DKRCE.PI.RL0.F7.ML...
  • Seite 137 - Wenn das Bedienfeld gesperrt ist, wird durch das Drücken irgendeiner Taste „LoC“ im Display angezeigt. - Die Tasten für NACH OBEN und NACH UNTEN gleichzeitig drei Sekunden lang drücken, um das Bedienfeld zu entsperren. Drei Sekunden lang wird dann „unl“ angezeigt. DKRCE.PI.RL0.F7.ML Installation Guide | ERC 211 | 137...
  • Seite 138 ±0,5 K zwischen -35 bis 25 °C, ±1 K über 25 °C Art der Maßnahme 1B (Relais) DO1-Verdichterrelais: 16 A, 16 (16) A, DIN EN 60730-1 Ausgang 10 FLA/60 LRA mit 230 V, UL 60730-1 16 FLA/72 LRA mit 115 V, UL 60730-1 | 138 Installation Guide | ERC 211 DKRCE.PI.RL0.F7.ML...
  • Seite 139 UL (USA und Kanada) (UL 60730-1) ENEC (DIN EN 60730-1) CE (Niederspannungs- und EMV-Richtlinie) Zulassungen EAC (GOST) RoHS 2.0 HACCP-Temperaturüberwachung in Übereinstimmung mit DIN EN 134785, Klasse 1, bei Verwendung mit dem Fühler AKS 12 DKRCE.PI.RL0.F7.ML Installation Guide | ERC 211 | 139...
  • Seite 140 Anw. 4 Heizung Heizthermostat (20 – 60 °C) Keiner Keiner Kühlung/ Keine (keine voreingestellte Anwendung), mit vereinfachter Anw. 5 Heizung Parameterliste APP 1/2/3 APP 4 Sair Sair V AC V AC | 140 Installation Guide | ERC 211 DKRCE.PI.RL0.F7.ML...
  • Seite 141 -1 = Service, 0 = AUS, 1 = EIN Nachtabsenkung -50.0 50.0 (Offset-Temperatur im Nachtmodus) Sollwertverschiebung Thermostat -50.0 50.0 (Offset-Temperatur) Dauer Schnellabkühlung Grenztemperatur Schnellabkühlung -100.0 200.0 Alarm Verzögerung für den Temperaturalarm unter normalen Bedingungen Hinweis: Verborgene Parameter sind grau dargestellt. DKRCE.PI.RL0.F7.ML Installation Guide | ERC 211 | 141...
  • Seite 142 Konfiguration: non = Zeit, Air = Sair (Lufttemperatur), dEF = S5 (Abtaufühler) Gesamte Verdichter-Betriebszeit bis zum Auslösen der Abtauung 0 = AUS Abtauverzögerung nach Schnellabkühlung 0 = AUS Hinweis: Verborgene Parameter sind grau dargestellt. | 142 Installation Guide | ERC 211 DKRCE.PI.RL0.F7.ML...
  • Seite 143 0.1 = Schritte von 0,1 °C 0.5 = Schritte von 0,5 °C 1.0 = Schritte von 1,0 °C Zähler Relais 1 (Eine Zählung = 100 Betriebszyklen) Vordefinierte Anwendungen Hinweis: Verborgene Parameter sind grau dargestellt. DKRCE.PI.RL0.F7.ML Installation Guide | ERC 211 | 143...
  • Seite 144 S32 = Verzögerung der Ausgänge bei Einschaltung Lufttemperatur (Sair) -100.0 200.0 Auslesen des vorhandenen Regelsollwerts -100.0 200.0 DI1-Eingang Status des Nachtbetriebs Verflüssigertemperatur (Sc) -100.0 200.0 Status Verdichterrelais Anzeige Firmware-Version Hinweis: Verborgene Parameter sind grau dargestellt. | 144 Installation Guide | ERC 211 DKRCE.PI.RL0.F7.ML...
  • Seite 145 Ein heit (Abtau- Anw. 1 Anw. 2 Anw. 3 Anw. 4 Anw. 5 ung) Alarmstatus Fehler Sair-Lufttemperaturfühler Hochtemperaturalarm Tieftemperaturalarm Hochspannungsalarm Tiefspannungsalarm Verflüssigeralarm Türalarm Standby-Alarm Externer Alarm DI Hinweis: Verborgene Parameter sind grau dargestellt. DKRCE.PI.RL0.F7.ML Installation Guide | ERC 211 | 145...
  • Seite 146 Diensten keinerlei Ansprüche gegenüber Danfoss oder Danfoss-Mitarbeiter ableiten, es sei denn, dass diese vorsätzlich oder grob fahrlässig gehandelt haben. Danfoss behält sich das Recht vor, ohne vorherige Bekanntmachung im Rahmen des Angemessenen und Zumutbaren Änderungen an Ihren Produkten - auch an bereits in Auftrag genommenen - vorzunehmen.
  • Seite 147 Notes DKRCE.PI.RL0.F7.ML Installation Guide | ERC 211 | 147...
  • Seite 148 Notes | 148 Installation Guide | ERC 211 DKRCE.PI.RL0.F7.ML...
  • Seite 149 Notes DKRCE.PI.RL0.F7.ML Installation Guide | ERC 211 | 149...
  • Seite 150 Notes | 150 Installation Guide | ERC 211 DKRCE.PI.RL0.F7.ML...
  • Seite 151 Notes DKRCE.PI.RL0.F7.ML Installation Guide | ERC 211 | 151...
  • Seite 152 KoolCode App Download the KoolCode App on your app store. More and more from your ERC controller! Scan this code to find out more about the ERC 211 parameter Download ERC 21X series www.danfoss.com/erc © Danfoss | ADAP-KOOL | 2018.10 Installation Guide | ERC 211 DKRCE.PI.RL0.F7.ML...