5
Notifications
5.1 Pictograms
Notifications are displayed as pictograms. If there are many notifications, washing will still
be possible but the end wash result will be impaired. Please therefore rectify any notifica-
tion as soon as possible. If you cannot rectify the notification, contact an authorised ser-
vice technician.
By tapping the pictogram, additional information will appear on the display.
Cause / meaning
Lack of rinse aid
Lack of detergent
Detergent dosing failed
Upper wash field does not
rotate
Lower wash field does not
rotate
For warewashers with an
integrated softener:
lack of salt
Warewasher with external
partial demineralisation
cartridge:
partial demineralisation
cartridge used up
Warewasher with external
full demineralisation cart-
ridge:
full demineralisation cart-
ridge used up
Hood is open
Lack of water
Quick guide PTD 901
Remedy
Replace the canister and prime the dosing device
(} page 41).
Replace the detergent canister (} page 41) and prime
the dosing device.
If the error is not cleared: Contact an authorised service
technician.
Remove the obstruction or clean or descale the jet
(} page 37).
Contact an authorised service technician.
Ensure the wash field is engaged correctly.
Remove the obstruction or clean or descale the jet
(} page 37).
Contact an authorised service technician.
Fill the salt container with regeneration salt. The display
disappears after filling the salt container after approx. 3
wash cycles have been completed and some of the salt
has dissolved.
Replace the partial demineralisation cartridge. Reset
the water countdown meter.
Have the resin of the full demineralisation cartridge re-
placed by an authorised service technician. Reset the
water countdown meter.
Close the hood.
Open the water supply.
Have the dirt trap cleaned by a service technician or
have a new dirt trap installed.
Have the solenoid valve repaired by an authorised ser-
vice technician.
|