Herunterladen Diese Seite drucken

EINHELL TKS 15/250-1 UV Bedienungsanleitung Seite 20

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
Anl.TKS 15-250-1 SPK1 V5
GB
guard must be able to move freely.
Fasten the extractor hose (13) to the extractor
adapter (16) and to the extractor socket of the
blade guard (2).
A suitable extractor system has to be connected
to the outlet of the extractor adapter (16).
To remove the saw blade guard, proceed in
reverse order.
Important!
The guard hood (2) must always be lowered
over the workpiece before you begin to cut.
7.4. Setting the splitter (Fig. 3/6/7/8)
Important! Pull out the power plug.
Set the blade (4) to max. cutting depth, move to
0° position and lock in place.
Remove the saw blade guard (see 7.3).
Take out the table insert (6) (see 7.5).
Slacken the fixing screw (20).
7.4.1. Setting for maximum cuts (Fig. 6/7/8)
Push up the splitter (5) until the gap between the
saw table (1) and the upper edge of the splitter
(5) equals approx. 10 cm.
The distance between the blade (4) and the
splitter (5) should be 5 mm.
Retighten the screw (20) and mount the table
insert (6) (Fig. 7).
7.5 Changing the table insert (Figure 7)
To prevent increased likelihood of injury the
table insert should be changed whenever it is
worn or damaged.
Remove the saw blade guard (2).
Remove the 2 countersunk head screws (34).
Take out the worn table insert (6).
To fit the replacement table insert, proceed in
reverse order.
7.6 Fitting/replacing the blade (Fig. 5)
Important! Pull out the power plug first.
Remove the table insert by undoing the two
countersunk head screws (see 7.5).
Undo the nut with a size 24 wrench on the nut
itself and a second fork wrench (size 13) on the
motor shaft (a) to apply counter-pressure.
Important! Turn the nut in the direction of
rotation of the saw blade.
Take off the outer flange and pull the old saw
blade off the inner flange by dropping the blade
at an angle.
Clean the blade flange thoroughly before fitting
the new blade.
Mount and fasten the new saw blade in reverse
order.
Important! Note the running direction. The
20
16.06.2005
8:16 Uhr
Seite 20
cutting angle of the teeth must point in
running direction, i.e. forwards (see the
arrow on the blade guard).
Refit and set the splitter (5) and the saw guard
(2) (see 7.3., 7.4.)
Check to make sure that all safety devices are
properly mounted and in good working condition
before you begin working with the saw again.
8.0. Using the saw
8.1. ON/OFF switch (Fig. 4)
To turn the saw on, press the green button .I. .
Wait for the blade to reach its maximum speed
of rotation before commencing with the cut.
To turn the machine off again, press the red
button "0".
8.2. Cutting depth (Fig. 4)!
Turn the hand crank (8) to set the blade (4) to
the required cutting depth.
Turn anti-clockwise:
larger cutting depth
Turn clockwise:
smaller cutting depth
8.3. Parallel stop
8.3.1. Stop height (Fig. 11-14)
The parallel stop (7) supplied with the bench-
type circular saw has two different guide faces.
For thick material you must use the stop rail (25)
as shown in Fig. 12, for thin material you must
use the stop rail as shown in Fig.11.
To change over the stop rail (25) to the lower
guide face you have to slacken the two knurled
screws (26) in order to disconnect the stop rail
(25) from the holder (24).
Remove the two knurled screws (26) through the
one slot (27) in the stop rail (25) and insert in the
other slot (31).
Remount the stop rail (25) on the holder (24).
The procedure for changing over to the high
guide face is similar.
8.3.2. Cutting width:
The parallel stop (7) has to be used when
making longitudinal cuts in wooden workpieces.
The parallel stop (7) can be mounted on either
side of the saw table (1).
The parallel stop (7) has to be mounted in the
guide rail (22) of the saw table (1).
The parallel stop (7) can be set to the required
dimension with the help of the scale (23) on the
guide rail (1).
You can clamp the parallel stop in the required

Werbung

loading

Diese Anleitung auch für:

43.406.50