Herunterladen Inhalt Inhalt Diese Seite drucken

Cleaning, Maintenance, Storage And Ordering Of Spare Parts - EINHELL TC-PG 55/E5 Originalbetriebsanleitung

Vorschau ausblenden Andere Handbücher für TC-PG 55/E5:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
6.3 Overload cut-out 2 x 230 V socket-outlets
Important! The generator is fi tted with an
overload cut-out.
This shuts down the sockets (3). You can restart
the sockets (3) by pressing the overload cut-out
(5).
Important! If this happens, reduce the electric
power you are taking from the generator or
remove any defective connected appliances.
Important! Defective overload cut-outs must
be replaced only by overload cut-outs of
identical design and with the same perfor-
mance data. If repairs are necessary, please
contact your customer service center.
6.4 Switching off the engine
Before you switch off the generator, allow it
to run briefly with no consumers so that it can
„cool down"
Move the key (Fig. 1/Item 10) to the „OFF"
position
Close the petrol cock
7. Cleaning, maintenance, storage
and ordering of spare parts
Switch off the motor and pull the spark plug boot
from the spark plug before doing any cleaning and
maintenance work on the equipment.
Notice! Switch off the machine immediately and
contact your service station:
In the event of unusual vibrations or noise
If the engine appears to be overloaded or
misfires
7.1 Cleaning
Keep all safety devices, air vents and the mo-
tor housing free of dirt and dust as far as pos-
sible. Wipe the equipment with a clean cloth
or blow it with compressed air at low pressure.
We recommend that you clean the device
immediately each time you have finished
using it.
Clean the equipment regularly with a moist
cloth and some soft soap. Do not use cleaning
agents
or solvents; these could at-
tack the plastic parts of the equipment. Ensu-
re that no water can seep into the device.
Anl_TC-PG_55_E5_SPK9.indb 24
Anl_TC-PG_55_E5_SPK9.indb 24
GB
7.2 Air fi lter
In this connection, please also read the service
information.
Clean the air filter at regular intervals, and
replace it if necessary.
Open both clips (Fig. 11/A) and remove the air
filter cover (Fig. 11/B).
Remove the filter elements (Fig. 12/C)
Do not use abrasive cleaning agents or petrol
to clean the elements.
Clean the elements by tapping them on a flat
surface. In cases of stubborn dirt first clean
with soapy water, then rinse with clear water
and air-dry.
Assemble in reverse order
7.3 Spark plug (Fig. 13-14)
Check the spark plug for dirt and grime after 20
hours of operation and if necessary clean with a
copper wire brush. Thereafter service the spark
plug after every 50 hours of operation.
Open the maintenance flap (Fig. 13/E).
Pull off the spark plug boot with a twist.
Remove the spark plug (Fig. 14/D) with the
supplied spark plug wrench.
Assemble in reverse order
7.4 Changing the oil and checking the oil le-
vel (before using the machine)
The motor oil is best changed when the motor is
at working temperature.
Place the generator on a slightly inclined sur-
face so that the oil drain plug is at the lower
end.
Open the oil filler plug.
Open the oil drain plug and let the hot engine
oil drain out into a drip tray.
After the old oil has drained out, close the oil
drain plug and place the generator on a level
surface again
Fill in engine oil up to the top mark on the oil
dip stick.
Important: Do not screw the dipstick in to
check the oil level, simply insert it up to the
thread.
Dispose of the waste oil properly.
7.5 Automatic oil cut-out
The automatic oil cut-out responds if there is too
little oil in the engine. In this case it will not be
possible to start the engine or it will cut out auto-
matically after a short period of time. It cannot be
started again until the engine oil has been topped
up (see point 7.4).
- 24 -
17.06.2019 07:18:06
17.06.2019 07:18:06

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

41.525.62

Inhaltsverzeichnis