CHECKING PRIMARY AIR IN MAIN BURNERS

All burners are provided with special injectors which do not require regulation of the primary air.
CP...-94G, CP...-98G
Burner 13,95 kW min. 4,8 kW
Burner Injector 1/100 mm
Min. output adjustment 1/100 mm
Pilot Injector
Consumption
CPB-98G
3 x Burner 10,5 kW min. 3,8 kW
Burner Injector 1/100 mm
Min. output adjustment 1/100 mm
Pilot Injector
Consumption
CPP-94G, CPPA-94G
Burner 23,5 kW min. 8,2 kW
Burner Injector 1/100 mm
Min. output adjustment 1/100 mm
Pilot Injector
Consumption

RULES FOR CONVERTING AND INSTALLING FOR OTHER TYPES OF GAS

Our appliances are tested and regulated for liquid gas (see plate inside).
The conversion or adaptation to another type of gas must be carried out by a specialised technician. The nozzles for the
various types of gas are in a bag supplied with the appliance and marked in hundredths of mm (see the "Technical Data"
table).

SUBSTITUTING THE NOZZLE IN THE MAIN BURNER

In order to operate inside the appliance, it is necessary to empty the water tub.
Remove the small knob from the panel by unscrewing it.
Remove the front fixing screws from the panel, remove the start up cable from the piezoelectric ignition device.
Using a suitable spanner, unscrew the nozzle and substitute it with the right one (see the "Technical Data" table).
The main burner does not require any regulation of the primary air.

SUBSTITUTING THE NOZZLE IN THE PILOT BURNER

The flame of the pilot burner has fixed air.
The only operation necessary is the substitution of the nozzle according to the type of gas.
It is therefore necessary to unscrew the screws as specified in the previous point; with a suitable spanner unscrew the
fitting and substitute the nozzle with a suitable one. With the right nozzle, the flame must lap the thermocouple.

Important!

After having carried out the conversion to another type of gas, it is necessary to update the data plate, indicating the
type of gas for which the appliance has been converted.
The instructions necessary for use are enclosed with the appliance.
Check the appliances for gas leaks.
Examine the flame of the pilot burner; it must lap the thermocouple and be blue, otherwise examine the nozzle of
the pilot burner.
Check the lighting and flame of the main burner.
All manuals and user guides at all-guides.com
GB
IT

BURNERS TECHNICAL DATA TABLE

12,68 kWh/Kg
G30
BUTANE
30 mbar
195
100
kg/h 1,100
165
190
kg/h 0,828
2 x 170
150
kg/h 1,853

CHECKING FUNCTIONING

40
IE
CH
12,87 kWh/Kg
G31
PROPANE
37 mbar
195
100
30
30
kg/h 1,083
165
190
30
30
kg/h 0,815
2 x 170
150
25
25
kg/h 1,826
3
9,45 kwh/m
st.
G20
NATURAL GAS
20 mbar
285
adjustable
51
m³ st./h 1,481
250
adjustable
41
m³ st./h 1,111
2 x 250
adjustable
41
m³ st 2,487