COLLECTION TRAYS
Clean the surface, removing grease, oil, food residue etc.

INSTRUCTIONS FOR MAINTENANCE

REMINDERS FOR THE MAINTENANCE TECHNICIAN

The manufacturer will not be liable for any damage or in-
jury resulting from failure to observe the following rules.
• Read this manual carefully. It provides important information
for safe installation, use and maintenance of the appliance.
• Disconnect the appliance electrical power supply, if present,
before proceeding with any operation.
• Installation, conversion to a different type of gas and applian-
ce maintenance must be carried out by qualified technicians
authorized by the manufacturer, in compliance with current
safety standards and the instructions given in this manual.
• Identify the specific appliance model. The model number is
detailed on the packaging and on the appliance data plate.
• The appliance must be installed in a well-ventilated room.
• Do not obstruct any air vents or drains present on the ap-
pliance.
• Do not tamper with appliance components.

CONVERSION TO A DIFFERENT TYPE OF GAS

See Chapter " Instructions for installation ".

COMMISSIONING

Following installation, conversion to a different type of gas
or any maintenance operations, check appliance ope-
ration. In the event of any malfunction, consult the next
paragraph"Troubleshooting".
GAS APPLIANCES
Switch on the appliance as directed in the instructions and re-
minders for use given in Chapter " INSTRUCTIONS FOR USE
" and check:
• the gas supply pressure ( see next Paragraph ).
• the correct ignition of the burners and the effectiveness of the
fumes removal system.
CHECKING THE GAS SUPPLY PRESSURE
• To measure the gas supply pressure use a manometer with a
minimum definition of 0.1 mbar.
• Remove the control panel.
• Remove the screw from the pressure test point PP and con-
nect the manometer to the test point.
• Make the measurement with the appliance in operation.
ATTENTION ! If the gas supply pressure is not within the limits
( Min. - Max ) indicated in Table T2, cease operation of the ap-
pliance and contact the gas utility company.
• Disconnect the manometer and retighten the retaining screw
on the pressure connection.

15 TROUBLESHOOTING

GAS FRY-TOP WITH TAP

The pilot burner does not light
Possible causes:
• Insufficient gas supply pressure.
• Blocked tubing or nozzle.
• Defective gas tap or valve.
• Igniter defective or not properly connected.
• Igniter or igniter wire defective.
Pilot burner goes out during use
Possible causes:
• Insufficient gas supply pressure.
• Defective gas tap or valve.
• Defective thermocouple or insufficient heating.
• Thermocouple incorrectly connected to gas tap or valve.
• Knob of gas tap or valve not pressed sufficiently.
The main burner does not light ( even though pilot is lit )
Possible causes:
• Insufficient gas supply pressure.
• Blocked tubing or nozzle.
• Defective gas tap or valve.
• Defective burner ( gas outlet holes clogged ).

GAS FRY-TOP WITH VALVE

The pilot burner does not light
Possible causes:
• Insufficient gas supply pressure.
• Blocked tubing or nozzle.
• Defective gas tap or valve.
• Igniter defective or not properly connected.
• Igniter or igniter wire defective.
Pilot burner goes out during use
Possible causes:
• Insufficient gas supply pressure.
• Defective gas tap or valve.
• Defective thermocouple or insufficient heating.
• Thermocouple incorrectly connected to gas tap or valve.
• Knob of gas tap or valve not pressed sufficiently.
The main burner does not light ( even though pilot is lit )
Possible causes:
• Insufficient gas supply pressure.
• Blocked tubing or nozzle.
• Defective gas tap or valve.
• Defective burner ( gas outlet holes clogged ).
Heating cannot be adjusted.
Possible causes:
• Defective gas valve.

16 REPLACING COMPONENTS

REMINDERS FOR REPLACING COMPONENTS.

• Disconnect the appliance electrical power supply, if present,
before proceeding with any operation.
• After replacing a gas system component, check for gas leaks
at connection points.