Herunterladen Inhalt Inhalt Diese Seite drucken
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 41
EN
use a duct of the maximum
diameter indicated in this
manual.
WARNING!
install screws or fixing
devices according to these
instructions can cause
electrical hazards.
Use
The hood is designed to be
used either as a ducting
version or as a filter version.

Ducting version

This version conveys the
fumes to the outside of the
building via an extraction
duct that is fixed to the
connecting flange.
The diameter of the
extraction duct must be the
same as that of the
connecting ring.
Warning! The duct is not
supplied and must be
purchased separately.
Failure to
Installation
In the horizontal section, the
extraction duct must have a
slight upwards inclination
(about 10°) so that it can
convey the air to the outside
more easily. If the hood is
fitted with activated carbon
filters, they should be
removed. Connect the hood
to the extraction ducts and
wall outlets that have a
diameter that is the same as
the air outlet (connecting
flange). Using ducts and wall
outlets that have a smaller
diameter will reduce suction
and lead to a large increase
in noise. We decline any
responsibility if these
instructions are not complied
with.
!
Use a duct of the
minimum
length necessary.
!
Use a duct with as few
bends as
possible (maximum angle:
18

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Universal klti9l4x

Inhaltsverzeichnis