Data Plate:
Installation Clearances: The MINIMUM clearance from combustible surfaces is;
Levelling:

4.2 APPLIANCE SPECIFICATION

Product name
Gas Category
Gas and Supply Pressure
Country of Destination
Injector Size
Gas Consumption
Product name
Appliance category
Gas and Supply Pressure
Country of Destination
Injector Size
Gas Consumption
Warning: This appliance shall be installed in conformity with the current regulations and used only in a well-
ventilated location. Consult the instructions before installing and using this appliance.
The data plate is located at the rear of the fryer
Sides
150 mm, and
Rear
50mm
Adequate clearance must also be provided for service.
To adjust the legs to level the unit to the floor and/or to slightly adjust the height of
the unit, raise the front of the unit and adjust the legs (ensure safe work practices).
Similarly, raise the back of the unit and adjust the legs. DO NOT LAY THE UNIT ON ITS
BACK. ENSURE THE UNIT IS LEVEL.
Gas Fryer
Type of appliances
I2H
G20 at 20 mbar
AT, BG, CR, CZ, DK,
EE, FI, GR, HR, HU,
IS, IE, IT, LV, LT, NO,
PT, RO, SK, SI, ES, SE,
CH, TR and GB
Ø 2.30 mm
34kW(3.6m3/h) for GF4 ;
27KW(2.9m3/h) for GF3
Gas Fryer
I3+(28-30/37)
G30 Butane at 28-30 mbar
and G31Propane at
37mbar
BE,CH,CY,CZ,ES,FR,
GB,GR,IE,IT,LT,LU,LV,PT,SK
,SI
Ø 1.5 mm
34kW (2681g/h) for GF4L; 27kW (2129g/h) for GF3L
www.combisteel.com
I2E
I2E+
G20 at 20
G20/G25 at
mbar
20/25 mbar
BE, FR
DE, LU, PL
Type of appliances
I3B/P(30)
G30 Butane and
G31Propane at 30mbar
BE,CY,DK,EE,FI,FR,HU,IT,LT
,NL,NO,SE,
SI,SK,RO,HR,TR,BG,
IS,LU,MT
Type A1
I
2(43.46 -45.3 MJ / m3 (0 ° C))
G25.3 at 25 mbar
NL
Ø 2.24 mm
32kW(3.4m3/h) for GF4
24kW(2.5m3/h) for GF3
I3B/P(50)
G30 Butane and
G31Propane at 50mbar
AT,CH,DE,SK
Ø 1.3 mm