When you have to connect the water supply on
the left side of the refrigerator (Fig. 11), detach
the two bottom hose clips (8, Fig. 10) for the sup-
ply and return lines in the recess on the rear
wall.
When the water lines are rerouted, safety
reasons demand that the cover plate (9, Fig. 11)
is reattached with the fixing screw and tooth lock
washer.
The supply and return lines for your IK 300 are
delivered with a length of 2.3 m.
If your installation needs longer lines, these can
be ordered from us.
Extensions to water lines are three metres long
with a
/
" connector.
3
4
The standard design features water hoses with
/
" connectors on the right or left of the applian-
3
4
ce as depicted in Fig. 12 (hatched areas).
The appliance's installation depth prevents
a connection to the water supply directly on the
rear wall.
The following values for the water pressure must
be observed:
1. min supply water pressure
1 bar
2. max supply water pressure
10 bar
The appliance will not operate properly when
the water pressure drops below 1 bar.
Exceeding the max water pressure of 10 bar can
damage the appliance.
A pressure reducing valve must be installed for
higher water pressures.
Any upstream water filter must be serviced
properly.
The return water hose must be no higher than
1 m above the floor (for a hose length of 6 m).