A AC input 16 A. Left to right: PE (earth/ground), L (phase), N (neutral).
AC input 50 A. Left to right: L (phase), N (neutral), PE (earth/ground).
B 2x RJ45 connector for remote control and/or parallel / three-phase operation
C Load connection. AC out1. Left to right: L (phase), N (neutral), PE (earth/ground).
D Load connection. AC out2.
16 A Left to right: N (neutral), L (phase), PE (earth/ground).
50 A Left to right: PE (earth/ground), L (phase), N (neutral).
E Terminals for 16 A: (left to right)
Voltage sense
Aux input 1
Starter battery plus +
(starter battery minus must be connected to service battery minus)
GND-relay
Temperature sensor
Terminals for 50 A: (left to right)
Temperature sensor
Aux input 1
Aux input 2
GND-relay
Starter battery plus +
(starter battery minus must be connected to service battery minus)
Programmable relay contacts K1
Programmable relay contacts K2
Voltage sense
F
Double M8 battery minus connection.
G Double M8 battery positive connection.
H Connector for remote switch:
Short left and middle terminal to switch "on".
Short right and middle terminal to switch to "charger only".
I
Alarm contact: (left to right) NC, NO, COM.
K Pushbuttons for set-up mode.
L
Primary ground connection M8 (PE).
M Dipswitches DS1- DS8 for set-up mode.
N Slide switches, factory setting 16 A: SW1= right (off) position, SW2 = right (off) position.
SW1: No application. To be used for future features.
SW2: INT(R) = internal GND relay selected, EXT(L) = external GND relay selected
GND relay: see E).
Slide switches, factory setting 50 A: SW1= down (off) position, SW2 = down (off) position.
SW1: down (off) = internal GND relay selected, up (on) = external GND relay selected
ext GND relay: see E).
SW2: No application. To be used for future features.
NL:
A Wisselspanning ingang AC-in 16 A. Van links naar rechts: PE (aarde), L (fase), N (nul).
Wisselspanning ingang AC-in 50 A: Van links naar rechts: L (fase), N (nul), GROUND (aarde).
B 2x RJ45 connector voor afstandbedieningspaneel en/of parallel en 3-fase bedrijf.
C Wisselspanning uitgang AC-out-1. Van links naar rechts: L (fase), N (nul), PE (aarde).
D Wisselspanning uitgang AC-out-2 16 A. Van links naar rechts: N (nul), L (fase), PE (aarde).
Wisselspanning uitgang AC-out-2 50 A. Van links naar rechts: PE (aarde), L (fase), N (nul).
E Aansluitklemmen voor 16 A: (van links naar rechts)
Voltage sense
Aux ingang 1
Start accu plus +
(de min van start accu moet vebonden zijn met de min van de service accu)
GND-relais
Temperature sensor
Aansluitklemmen voor 50 A: (van links naar rechts)
Temperature sensor
Aux ingang 1
Aux ingang 2
GND-relais
Start accu plus +
(de min van start accu moet verbonden zijn met de min van de service accu)
Relais contacten K1
Relais contacten K2
Voltage sense
F
Dubbele M8 accu min aansluiting.
G Dubbele M8 accu plus aansluiting.
H Aansluitklemmen voor afstandbedieningsschakelaar.
Verbind de linker klem en de middelste klem om de MultiPlus aan te schakelen.
Verbind de rechter klem en de middelste klem voor 'alleen laden'.
I
Alarm contact: (van links naar rechts) NC, NO, COM.
(to connect ext
(to connect