For public areas, the respective valid accident prevention regulations must be respected. The LED LMCT
TUBE 144 RGB must be installed out of the reach of people. Overhead installation is only allowed when
additional safety measures are taken.
If the LED LMCT TUBE 144 RGB shows any kind of inner or outer damage, for example deep scratches,
splintered tube or cable/plug damage, then any further use is forbidden. If the LED LMCT TUBE 144 RGB
shows any kind of damage during use, then the stick must not be touched and must be disconnected from
the mains as well as unplugged from the mains socket. A damaged LED LMCT TUBE 144 RGB must not be
repaired with tape or similar resources. It must be either disposed of according to local environmental
regulations or taken to a professional for repairs.
Allowed temperature range is between -5° C und +45° C. Maximal allowed atmospheric humidity is 75% rel.
humidity (not condensed).

Hanging installation

Please consider the EN 60598-2-17 and the respective national norms during the
installation! The installation must only be carried out by an authorized dealer!
The installation of the device has to be built and constructed in a way that it can hold 10 times the weight for
1 hour without any harming deformation.
The installation must always be secured with a secondary safety attachment, e.g. an appropriate catch net.
This secondary safety attachment must be constructed in a way that no part of the installation can fall down
if the main attachment fails.
When rigging, derigging or servicing the device staying in the area below the installation place, on bridges,
under high working places and other endangered areas is forbidden.
The operator has to make sure that safety-relating and machine-technical installations are approved by an
expert before taking into operation for the first time and after changes before taking into operation another
time.
The operator has to make sure that safety-relating and machine-technical installations are approved by an
expert after every four year in the course of an acceptance test.
The operator has to make sure that safety-relating and machine-technical installations are approved by a
skilled person once a year.
Procedure:
The device should be installed outside areas where persons may walk by or be seated.
IMPORTANT! OVERHEAD RIGGING REQUIRES EXTENSIVE EXPERIENCE, including (but not limited to)
calculating working load limits, installation material being used, and periodic safety inspection of all
installation material and the device. If you lack these qualifications, do not attempt the installation yourself,
but instead use a professional structural rigger. Improper installation can result in bodily injury and or
damage to property.
The device has to be installed out of the reach of people.
The device must never be fixed swinging freely in the room.
Caution: Devices in hanging installations may cause severe injuries when crashing down! If you have
doubts concerning the safety of a possible installation, do NOT install the device!
Before rigging make sure that the installation area can hold a minimum point load of 10 times the device's
weight.
DANGER TO LIFE!