Note: In the case of three-phase models, swapping two phases may cause the electric motors
to run in the reverse direction, which can lead to damage. For this reason, the unit has a
built-in protective device that breaks the circuit if the connection is not correct. If the red LED
above this safety device lights up, you must swap the connections of two of the phase
wires.
Model
HYDRO PRO5
HYDRO PRO7
HYDRO PRO10
HYDRO PRO13
HYDRO PRO18
HYDRO PRO22
HYDRO PRO22T
HYDRO PRO26
HYDRO PRO26T
3.8 Initial operation
Note: In order to heat the water in the pool (or hot tub), the filter pump must be running
to cause the water to circulate through the heat pump. The heat pump will not start up
if the water is not circulating.
After all connections have been made and checked, carry out the following procedure:
1. Switch on the filter pump. Check for leaks and verify that water is flowing from and to the
swimming pool.
2. Connect power to the heat pump and press the On/Off button
panel. The unit will start up after the time delay expires (see below).
3. After a few minutes, check whether the air blowing out of the unit is cooler.
4. When turn off the filter pump , the unit should also turn off automatically , if not, then adjust
the flow switch.
Fuse or
Voltage (V)
circuit
breaker (A)
220–240
220–240
220–240
220–240
220–240
220–240
3x 380
220–240
3x 380
Rated current (A)
15
4.1
15
4.7
20
7
25
9.1
40
13.4
45
15
20
6.6
50
17.4
25
7.7
- 16 -
Wire diameter mm
(with max. 15 m length)
2x 1.5 + 1.5
2x 1.5 + 1.5
2x 2.5 + 2.5
2x 2.5 + 2.5
2x 6 + 6
2x 6 + 6
4x 2.5 + 2.5
2x 6 + 6
4x 2.5 + 2.5
on the electronic control
2