8 Maintenance

8.1 Maintenance
You must perform visual and functional
tests at regular intervals.
Visual inspection
Perform a visual inspection once a month:
f Make sure that the smoke intake
lamella are not blocked
(e.g., by dust, dirt, paint).
f Make sure that the device is not
damaged, and is securely mounted
on location.
Functional check
To ensure that the devices are operation-
al, you must check the function of each
device and the group using a test tone.
f If no test tone sounds, you must
replace the device.
Test tone device
Trigger a test tone at least once every
3 months:
f Press and hold the testing / stop but-
ton for about 2 to 3 seconds.
72
Operating Manual: FRWM200 - Smoke Alarm Device with Radio Link
Short acoustic signal, single
device
In addition, we recommend checking the
functioning of the device twice a year with
a „Smoke Detector Test Spray".
Radio group test tone
Trigger a test tone every 3 to 6 months:
f Observe chapter 6.6 „Group con-
nection test" on page 64.
Test tone for shared radio group
Trigger a test tone every 3 to 6 months:
f Observe chapter 6.7 „Shared group
connecting test" on page 64.
8.2 Cleaning
Note the following when cleaning:
f Remove the device from the mag-
netic carrier.
f Clean the device with care, e.g. with
a vacuum cleaner and a wet cloth.