6.3 Finalising radio group
In order to complete a newly established ra-
dio group, you must exit the learning mode.
You have two options for this purpose:
f Wait 10 minutes.
f or briefly push the radio button on
the device last put into operation until:
All signal LEDs "off"
5 Radio group is in operation.
f To verify, perform the connection
test (see chapter 6.6 „Group connec-
tion test" on page 64).
6.4 Bring the radio group into
learning mode
You can extend an existing radio group
by bringing the radio group in the learning
mode. Observe the following:
(1) Press and hold the radio button with
splint pin on any device until:
All signal LEDs "off"
62
Operating Manual: FRWM200 - Smoke Alarm Device with Radio Link
(2) Release radio button.
5 Device max. 10 minutes in
learning mode.
(3) Add additional devices.
f Observe chapter 6.2 „Expand radio
group (learning mode)" on page 61.
6.5 Set up shared radio group
For special applications, it may be useful
to set up a shared radio group (e.g., in
the corridor of an apartment building).
A central radio group (corridor), which is
associated with one or more other radio
groups (flats), takes over the function of
the shared radio group. The other radio
groups form subgroups.
EN