4.1.5 VERTICAL INSTALLATION ON THE COVER

For installing in a vertical position, fit the anti-vibration supports
supplied with the unit on the cover, and then fix the whole
structure to the support.
See point 4.1.2 for the INSTALLATION CONDITIONS.
Any use other than the intended use of the
unit may cause serious injury and even
death!
When installing vertically DO NOT use the foot supplied with
the unit as this is only suitable for horizontal installations.
Remove the covers over the openings before checking the
direction of rotation and before final connection.
NOTE FOR THE USER
A foot for fitting the unit in a vertical position on the cover is
available as an accessory.
The foot has fixing holes. Use all the holes and suitable bolt
types.
WARNING!
Check the direction of rotation in the motor.
(See point 4.2.1 ROTATION DIRECTION)
When connecting the unit cabin to the ducting, do so using the
flanges on the silencer housings and form suitable connections
using flexible hoses. Avoid rigid connections that may impose
loads and give rise to harmful vibrations.
Fit the flanges on the silencer housings complete with gaskets
again, and tighten.
4.2

ELECTRIC MOTOR

Electrical danger!
Inappropriate behaviour may result in serious injury and
even death!
Work
on
electrical
maintenance) is only to be done by qualified, authorised
electricians!
Before starting to work on the unit or plant, the following
precautions must be taken:
Make sure that the line is NOT switched on.
Adopt measures to prevent it being switched on again.
Only open the terminal board box after checking that the
power is off altogether!
The terminal board box must not contain:
Foreign bodies
Impurities
Moisture.
Close the cover on the terminal board box and seal the
openings in the cable glands in order to prevent dust, water,
and moisture to penetrate.
Check the seals periodically.
Should you touch a defective unit there may be a danger
of electric shock!
Fit a motor trip-switch.
Have the unit's electrical system checked by an
electrician on a regular basis.
The electric motor is sized to work at an ambient temperature
between -15° C (+5° F) and +40° C (+104°F), and a maxi mum
altitude of 1000 m above sea level.
Under other conditions the motor cannot be used at full load
and so difficulties may arise for starting, particularly with a
single-phase power supply for the motors.
equipment
(installation
and
WARNING!
A maximum of n° 6 evenly distributed starts per hou r, is
allowed.
Failure to comply with this may seriously damage the unit.
4.2.1

CONNECTION

WARNING!
Connecting the motor incorrectly may seriously damage the
unit.
The power supply for the motor and any auxiliary equipment
must be provided using cables of suitable section to avoid
abnormal overheating and great voltage drops.
Check that the details on the nameplate are compatible with the
line voltage and frequency.
A voltage tolerance of ±10% compared to the nominal value is
admissible.
Connect the motor's earth cable to the relevant terminal marked
with this symbol
supply and check the dispersion capacity.
The earth cable can be recognised by its colour (yellow/green).
This connection to the main supply must be formed as shown in
the wiring diagram contained in the terminal board box.
Use the cable gland openings to allow power supply cables to
pass into the terminal board box.
Proceed to tighten the power supply cables, taking the section
of the electrical cables into account each time.
The terminal boards for the electrical connections must be
tightened properly to avoid high contact resistances and
resulting overheating.
Check that the insulation gaps between the various conductors
are kept in the air and between surfaces, as indicated in the
standards.
All the screws used to close the terminal board must be
tightened properly.
immediately, using screws of the same or better quality.
The connection must guarantee:
-
Long-lasting safety.
-
That no wire ends are sticking out.
Fuses do not constitute protection for the motor, but merely
protect against short-circuits.
Size the fuses according to the peak currents, especially when
using direct starting.
Protection with a (thermal or amperometric) trip switches is
essential to deal with risks of overloading, a loss of one phase
in the mains supply, excessive voltage fluctuations, or the rotor
getting stuck.
Set the motor trip switch using the current value shown on the
nameplate as a maximum.
4.2.2

INVERTER POWERED ELECTRIC MOTOR

WARNING!
A maximum of n° 6 evenly distributed starts per hou r, is
allowed.
Failure to comply with this may seriously damage the unit.
WARNING!
The unit's nominal pressure or vacuum characteristics for
service at mains frequency cannot be maintained if the unit
is powered via an inverter.
If an inverter is used for the power supply the installer is
responsible for the checks and any steps necessary to comply
with the immunity and emission limits laid down by the
standards.
GB - 23/64
always before connecting to the mains
Damaged screws must be replaced