Filling the Refrigerant
• Use the refrigerant R32 suitable for the unit. Make sure that you do not mix different
refrigerants.
• The refrigerant tank should be kept straight throughout the time the refrigerant is
being charged into the air conditioner.
• Stick a sticker with the refrigerant label on the air conditioner.
• Do not pour too much refrigerant into the air conditioner.
• After you have filled the refrigerant into the air conditioner, carry out a leak test. A
leak test should also be carried out before removing the refrigerant.
Transporting and Storing the Refrigerant Tank
• Use a flammable gas detector before unloading and opening the refrigerant
container.
• Fire sources and smoking are prohibited during transport and in the storage area of
the container.
• Follow local laws and regulations.