M4M 2X NETZANALYSEGERÄT BENUTZERHANDBUCH

2. Verpackungsinhalt

Verpackungsinhalt
1
2
3
4
Die Anzahl und Art der abnehmbaren Klemmen in der Verpackung variiert je nach Version. In der
nachstehenden Tabelle finden Sie die in jeder Packung enthaltenen abnehmbaren Klemmen.
Produktname
M4M 2X MODBUS
M4M 2X ETHERNET
M4M 2X
Ethernet PQ1
M4M 2X
Ethernet PQ1+RTS
M4M 2X
Ethernet PQ2
M4M 2X
Ethernet PQ2+RTS
M4M 2X
Ethernet RTS
M4M 2X Modbus PQ1
M4M 2X
Modbus PQ1+RTS
M4M 2X
Modbus PQ2
M4M 2X
Modbus PQ2+RTS
M4M 2X Modbus RTS
1
Netzanalysegerät M4M 2X
Installationshandbuch
Kalibrierschein
Abnehmbare Klemmen
Stromein gangs-
Spannungs ein-
klemme
gangs klemme
(8-polig)
(4-polig)
2
M4M Calibration Certificate
Contact us
3.M4M 2X features
5.Access throgh software
ABB S.p.A.
Electrification Business
According to the product version and
Viale dell'Industria, 18
functionality packages, M4M 2X features are:
Download Ekip Connect desktop
20009 Vittuone (MI) Italy
software from ABB Library
https://new.abb.com/low-voltage
M4M 2X
Current, Voltage,
Warning! Installation by person
frequency
with electrotechnical expertise
5.1.Access For M4M 2X Modbus
Active, Reactive and
only.
Apparent power
Warnung! Installation nur durch
1. Download Ekip Connect desktop
Test Conditions
elektrotechnische Fachkraft.
Power factor
software
Avvertenza! Fare installare solo da
V1
2. Click on "Configure" under Serial port.
V2
V3
I1
I2
I3
Operating timer,
un elettricista qualificato.
No.
PF
countdown timer
[V]
3. Select communication parameters and
[V]
[V]
[A]
[A]
[A]
Active, Reactive and
press "Ok":
Apparent energy
#1
230
230
230
6
6
6
1
Default parameters
4 quadrants Energy
(Import/Export)
Baudrate
19200
Network analyzer
THD (I, VLN, VLL)
#2
230
230
230
0,9
0,9
0,9
1
Parity
Even
Neutral current
Calculated
INSTALLATION MANUAL
M4M 2X via Ekip Connect
YouTube
Slave address
1
desktop software guide
Tutorials Playlist
Single alarms
25
#3
230
230
230
0,15
0,15
0,15
1
M4M 2X
4. Click on "Scan" in order to access M4M 2X
Demand values (average)
Basic
5.2.Access to M4M 2X Ethernet
Max/min values
Basic
#4
230
230
230
6
6
6
0,5 ind.
3-phase 4-wire network with 3CTs
1. Download Ekip Connect desktop
© Copyright 2022 ABB S.p.A. All rights
Warnings, alarms and
software
reserved. Specification subject to change
errors logs
#5
230
230
230
0,9
0,9
0,9
0,5 ind.
without notice.
2. Click on "Configure" under Ethernet
Digital Outputs
2
3. In the section "IP addresses", write the IP
1.Packaging Content
+PQ1
address of the device and click "+".
#6
230
230
230
0,15
0,15
0,15
0,5 ind.
Individual Harmonics
25th
Network analyzer M4M 2X
Unbalances
Default parameters
Installation manual
Historicals logs
Intermediate
#7
230
230
230
1,5
1,5
1,5
1
IP address
192.168.1.12
Calibration certificate
RTC
Removable terminals for wiring
3-phase 4-wire network with 1CT
+PQ2
4. Click on "Scan" in order to access M4M 2X.
#8
230
230
230
0,2
0,2
0,2
1
Individual Harmonics
40th
2.Mounting
Unbalances
6.First Commissioning
Historicals logs
Advanced
#9
230
230
230
1,5
1,5
1,5
0,5 ind.
2.1.Assembly
RTC
To start to use the analyzer it is mandatory to
Neutral current
Measured
configure the basic setting (type of network,
#10
230
230
230
0,2
0,2
0,2
0,5 ind.
+RTS
CT ratio and VT ratio). Configuration is
TS35
possible via EPiC Mobile or Ekip Connect (see
Tariffs
6
chapter 4 and 5).
#11
230
230
230
6
6
6
0,5 ind.
3-phase 3-wire network with 1CT
Complex alarms with
4
6.1. Type of network
logics
RTC
#12
230
Select the type of network among the
230
230
0,9
0,9
0,9
0,5 ind.
Programmable I/O
4
1
following ones
1
instead of 2 Digital Outputs
#13
230
230
230
0,15
0,15
0,15
0,5 ind.
Parameter
Description
4.Access through mobile app
#14
3Ph/4W/4CT
58
58
3-phase 4-wire + 4CTs
58
6
6
6
1
7,5 mm
3-phase 3-wire network with 3CTs
3Ph/4W/3CT
3-phase 4-wire + 3CTs
S4M Mobile app
#15
3Ph/4W/1CT
58
58
3-phase 4-wire + 1CT
58
6
6
6
0,5 ind.
3Ph/3W/1CT
3-phase 3-wire + 1CT
#16
230
230
230
6
-
6
1
1
3Ph/3W/3CT
3-phase 3-wire + 3CTs
iOS
Android
3Ph/3W/2CT
3-phase 3-wire + 2CTs
1. Scan the QR code above to install S4M
#17
230
230
230
0,9
-
0,9
1
2. On the "Devices" tab, tap "New device"
1Ph/2W/1CT
1-phase 2-wire + 1CT
3-phase 3-wire network with 2CTs
3. Accept to turn your smartphone
Bluetooth on and grant S4M permission
#18
230
230
230
0,15
-
0,15
1
2Ph/3W/2CT
2-phase 4-wire + 2CTs
to use the camera
4. Select the M4M you want to configure
from the list of detected devices
#19
230
230
230
6
-
6
0,5 ind.
2
6.2.Current Transformer ratio
5. Enter the passkey. Default passkey is 00
+ last four digits of device Serial Number
Set the Current Transformer ratio according
(laser printed on the device).
#20
230
to transformation ratio of the installed
230
230
0,9
-
0,9
0,5 ind.
current transformers.
#21
230
230
230
0,15
-
0,15
0,5 ind.
3
2-phase 3-wire network with 2CTs
• CT secondary can either be 1 or 5.
CT primary value cannot be lower
than CT secondary value.
• In case of PQ2 functionality
package, if 4th CT is used to
This Calibration Certificate may not be reproduced, in whole or in part,
measure the neutral current,
CT ratio for Neutral has to be
without written permission of ABB
configured.
6.3.Voltage Transformer ratio
1-phase 2-wire network with 1CT
Example:
2.2.Wiring Diagram
S/N
Default PIN
Set the Voltage Transformer ratio, if used,
according to the transformation ratio of the
3-phase 4-wire network with 4CTs (only
N223AB0127
000127
installed voltage transformers.
available with functionality package PQ2,
Neutral current measured)
In case of direct insertion, 400/400V
6. Set the M4M password
value shall be used.
7. After M4M is paired successfully, on
S4M you will be asked to choose your
preferred mode of configuration.
The "Configuration wizard" is the
recommended choice for first time users
For current measurement, please
Note that to start configuration with S4M,
notice that it is needed to fasten the
M4M firmware version must be 2.6.11 or
screw-type terminal to the device
higher.
with the two screws.
4
Hilfsversor gungs-
Programmier bare
Digitale
klemme
Ein-/Ausgangs-
Ausgangs klemme
klemme
(2-polig)
(5-polig)
(3-polig)
3
Test
Test Description
Accuracy
Result
Results
Limit
Verification –
-0,01%
±0,5%
Passed
Active energy (Import)
Verification –
-0,01%
±0,5%
Passed
Active energy (Import)
Verification –
-0,01%
±0,5%
Passed
Active energy (Import)
Verification –
-0,01%
±0,5%
Passed
Active energy (Import)
Verification –
-0,01%
±0,5%
Passed
Active energy (Import)
Verification –
-0,01%
±0,5%
Passed
Active energy (Import)
Verification –
-0,01%
±0,5%
Passed
Active energy (Import)
Verification –
-0,01%
±0,5%
Passed
Active energy (Import)
Verification –
-0,01%
±0,5%
Passed
Active energy (Import)
Verification –
-0,01%
±0,5%
Passed
Active energy (Import)
Verification –
-0,01%
±0,5%
Passed
Active energy (Import)
Verification –
-0,01%
±0,5%
Passed
Active energy (Import)
Verification –
-0,01%
±0,5%
Passed
Active energy (Import)
Verification –
-0,01%
±0,5%
Passed
Active energy (Import)
Verification –
Passed
-0,01%
±0,5%
Active energy (Import)
Verification –
-0,01%
±0,5%
Passed
Active energy (Import)
Verification –
-0,01%
±0,5%
Passed
Active energy (Import)
Verification –
-0,01%
±0,5%
Passed
Active energy (Import)
Verification –
-0,01%
±0,5%
Passed
Active energy (Import)
Verification –
-0,01%
±0,5%
Passed
Active energy (Import)
Verification –
-0,01%
±0,5%
Passed
Active energy (Import)
Analoge
RS485-Klemme
Ausgangs klemme
(3-polig)
(3-polig)