Herunterladen Inhalt Inhalt Diese Seite drucken
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 4
6.9

Flushing

WARNING: to prevent injuries while
working with the refrigerant, read and
follow the instructions and warnings in this
manual, and wear protective clothing, such
as safety glasses and gloves.
WARNING: DO NOT disconnect the
service connections during the flushing
procedure. The refrigerant may escape
from the connections and exposure may
cause injury.
!
The flushing kit contains a replaceable filter that
can hold particles of certain dimensions, which
can clog. At the end of the flushing cycle, check the
pressure in the A/C system on the high pressure
gauge (red) and check the adapter for complete
refrigerant removal.
!
If there is still pressure or refrigerant remains,
close the flushing cycle and go to the recovery
function to recover the refrigerant with the high
pressure (red) and low pressure (blue) hoses.
Then perform the filter maintenance and repeat the
flushing procedure.
The flushing function must be performed using a
flushing kit approved by the vehicle manufacturer. Also
refer to the instructions included in the adapter while
performing the following procedure.
1. Check that the filter of the flushing device is not
clogged.
2. Install the flushing device according to the flushing
device instructions on the back of the station.
Do not make any connections at this stage.
3. Remove the oil drain bottle from the Bosch station.
4. Empty it and dispose of the oil according to the
law.
5. Reinstall the oil drain bottle on the station.
6. Recover all refrigerant from the A/C system to be
flushed.
7. Record the amount of oil collected during the
recovery. This quantity must be replaced with the
oil collected during flushing, if any.
!
The amount of oil collected and documented
during the A/C system flushing does not include
the amount of oil collected during the initial
recovery.
Robert Bosch GmbH
Instructions for use | ACS 553 | 57 |
8. Check that there is at least 6.0 kg (13.2 lb) of
refrigerant in the station.
i
To complete the A/C system flushing effectively,
ensure that the station has at least 6.0 kg (13.2 lb)
of refrigerant in the internal tank.
i
If the station does not contain at least
6.0 kg (13.2 lb) of refrigerant in the tank, see the
Tank filling section.
9. Disconnect the station from the vehicle.
10. Refer to the vehicle maintenance manual and
connect the appropriate flushing adapters and
bypass hoses.
11. Connect the low pressure service hose (blue)
directly to the flushing kit filter.
12. Remove the high pressure service connection (red)
and connect the high pressure service hose (red)
to the A/C system suction hose adapter.
13. Use the supplied hose to connect the A/C system
drain hose adapter to the inlet of the flushing
device.
14. Connect the hoses following the instructions
provided with the flushing kit.
15. Call up the Main Menu.
16. Select
.
17. Select
.
18. Select Functions.
19. Select System Flush.
20. Enter the service data and confirm with
(see chapter 6.1).
« The station displays a message to confirm that
the flushing kit is properly connected.
21. Select
to continue.
22. The station generates a vacuum in the A/C system
for the programmed time interval.
« After the vacuum has been carried out, the sta-
tion performs a leak check.
23. After a small charge, the refrigerant charged is
recovered through the low pressure service hose.
en
|
1 689 989 627
2021-03-01

Werbung

Kapitel

Inhaltsverzeichnis
loading

Inhaltsverzeichnis