Message on the display
Power board communication
failed
Unsuccessful pressure test
Check for leaks
Empty external tank
Full tank. Remove refrigerant
from the internal tank before
continuing
Expired trial time.
Activation of the required unit
to continue using it.
Activate now?
Vacuum test failed. Check for
leaks
Robert Bosch GmbH
Cause
The communication with the power board
failed
There is a leak in the A/C system of the
vehicle.
Failure to transfer refrigerant to the
internal tank because the external tank is
empty.
Internal tank too full to recover more
refrigerant.
Failure to register and activate the machine
within 30 days of initial start-up causes the
machine to lock and the impossibility to
use it.
There is a leak in the A/C system.
Diagnostic messages | ACS 553 | 65 |
Solution
Restart the station. If the problem persists, contact
an authorized Bosch service center for more
information.
Exit the current test and repair the A/C system of
the vehicle.
Exit the current test and replace the external tank.
Perform a refilling process to remove refrigerant
from the internal tank before performing any further
recovery attempt.
Select
and see the Unit activating section of this
manual to register the station.
Exit the current test and repair the A/C system of
the vehicle.
1 689 989 627