Herunterladen Inhalt Inhalt Diese Seite drucken

Electrical Connection; Connections On The Ls4 As-Interface - Siemens SIGUARD LS4-4 Anleitung

Laserscanner
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

4.3

Electrical connection

4.3.1 Connections on the LS4 AS-Interface

X1
AS-Interface connection (data and auxiliary power supply)
X2
Connection for the AS-Interface address programming device
X3
Connection for the switching of protective fields
X4
Restart button connection
X5
Optical PC interface
Fig. 4.3-1:
Connections on the LS4 AS-Interface
Socket/
Function
plug
X1 (plug) AS-Interface data
and 24 VDC aux-
iliary power sup-
ply
X2
Bus address pro-
gramming input
X3
Switching of pro-
(socket)
tective fields
X4 (plug) Restart button
Table 4.3-1:
FE – functional earth: this must be supplied in order to give improved EMC (electro-
magnetic compatibility), and should be connected to the functional earth of the ma-
chine or system.
36
X1
X2
PIN 1
AS-inter-
face +
AS-inter-
face +
SF 1
n.c.
Connection pin assignment of the LS4 AS-Interface
X5
X3
X4
PIN 2
PIN 3
V
AS-inter-
face -
n.c.
AS-inter-
face -
SF 2
SF 3
Restart
n.c.
PIN 4
PIN 5
+ 24 V
FE
DC
n.c.
n.c.
SF 4
+ 24 V
DC
+ 24 V
n.c.
DC

Quicklinks ausblenden:

Werbung

Kapitel

Inhaltsverzeichnis
loading

Inhaltsverzeichnis