Herunterladen Inhalt Inhalt Diese Seite drucken

Troubleshooting - Westfalia 82 44 29 Bedienungsanleitung

Hauswasserwerk 1100 w
Inhaltsverzeichnis

Werbung

Faults
Motor does not
run
Pump does not
prime
Insufficient
pumping rate
Thermostat
switches off the
pump
Pump switches
on and off too
often

Troubleshooting

Cause
Power supply not connected
Impeller blocked
The thermostat has switched
off
Filter insert dirty
Pump housing without water
Air in the suction line
Max. suction height
exceeded
Suction height too high
Filter insert is dirty
Water lever is falling rapidly
Pump performance is reduced
by foreign bodies
Motor overloaded
Friction through foreign bodies
is too high
Lead in the water bag
Pressure in the tank is too
low
Solution
Check power mains
Have the booster pump
dismantled and cleaned (by
service workshop)
Clean
Fill water into the pump
housing
Check proper sealing of the
Suction line
Check suction height
Check suction height
Clean filter insert
Place the suction hose at a
deeper level
Please the pump and replace
worn parts (by service
workshop)
Have the pump dismantled and
cleaned
Prevent the intake of foreign
bodies
Have the water bag replaced by
a service workshop
Re-fill air into the pressure tank
23

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis