Herunterladen Inhalt Inhalt Diese Seite drucken

Installation; Hoses And Connections; Connecting A Water Separator; Lubrication - Chicago Pneumatic CP 4608 P Sicherheits- Und Betriebsanleitung

Hand-druckluftniethämmer
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 42
Safety and operating instructions
Eject warning label
The label indicates that the machine must be
disconnected from the power source before
removing or changing the inserted tool.
Warning label
PARTS CAN EJECT
FROM TOOL
TO PREVENT
INJURY
DRAIN AND DISCONNECT
AIR SUPPLY FROM TOOL
BEFORE REMOVING LOCK
SPRING FROM RETAINER
Parts can eject from tool. To prevent injury, drain
and disconnect air supply from tool before removing
lock spring from retainer.

Installation

Hoses and connections

A
C
B
Compressed air source
A.
Water separator (optional)
B.
C.
Oiler (optional)
D.
Max. 10 feet (3 meter) compressed air hose
between the oiler and the machine.
Check that you are using the correct
recommended operating pressure, 87 psig (6 bar
(e)).
The maximum permissible air pressure, 90 psig
(6.2 bar (e)), must not be exceeded.
Blow any impurities out of the compressed air
hose before connecting it to the machine.
14
P157290
D
CP 4608 P, CP 4611 P, CP 4608 D, CP 4611 D
Select the correct dimension and length for the
compressed air hose. For hose lengths up to 100
feet (30 meters), a hose with a minimum internal
diameter of
3
in. (19 mm) should be used. If the
4
hose length is between 100 and 330 feet (30 and
100 meters), a hose with a minimum internal
diameter of 1 in. (25 mm) should be used.
Connecting a water
separator
The length of the air hose between the compressor
and the water separator must be such that the water
vapour is cooled and condenses in the hose before
reaching the water separator.
If the ambient temperature is below 32 °F (0 °C) the
hose must be short enough to prevent the water
from freezing before reaching the water separator.

Lubrication

The lubricant is important for the machine s function
and has a great impact on the service life. In order
to supply the correct volume of oil, an oiler should
be connected to the air hose. The use of a Chicago
Pneumatic air line oiler is recommended. To
guarantee good lubrication, the length of the air
hose between the oiler and the pneumatic tool
should not exceed 10 feet (3 m).
Too much lubrication can cause starting problems,
low power or uneven performance.
Use a synthetic lubricant such as CP Airolene Plus
Tool Oil or mineral oil with the properties
recommended in the table below.
Temperature
Lubricant
range °F (°C)
CP Airolene Plus
-4 to +120
Tool Oil
(-20 to +50)
Air tool oil
-4 to +60
(-20 to +15)
Air tool oil
+60 to +120
(+15 to +50)
It is recommended that the oil contains a
rust-inhibitor.
9800 0551 90e | Original instructions
Viscosity
-
100-150 SUS
(ISO VG 22-32)
225-350 SUS
(ISO VG 46-68)

Werbung