Herunterladen Diese Seite drucken

Startup - AL-KO HW 3000 Betriebsanleitung

Vorschau ausblenden Andere Handbücher für HW 3000:

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
en
In day-to-day operation (automatic
ADVICE
mode) you must take measures to
exclude the possibility that flooding
of the room occurs as a result of mal-
functions on the unit.
Connect the suction line
1. Select the length of the suction line (Fig. B
-16) so that the house water system cannot
run dry. The suction line must always be at
least 30 cm under the surface of the water.
2. Connect the suction line. Make sure that the
connection does not leak, without damaging
the thread.
We recommend using flexible hoses at
the pump inlet (Fig. A -1). This prevents
mechanical tension or pressure from
being exerted on the house water sys-
tem.
3. A pre-filter must be installed between the suc-
tion line and the pump inlet if the water has
a small amount of sand in it. Ask your expert
dealer.
4. Always lay the suction line with an uphill gra-
dient.
If the suction height is more than 4m, you
ADVICE
must use a suction hose having a diame-
ter greater than 1". We recommend the
use of an AL-KO suction unit with suction
hose, suction filter and flow-back stop.
Ask your expert dealer.
Mounting the pressure line
1. Screw the connecting nipple (Fig. B -13) with
the round seal ring (Fig. B -14) into the pump
outlet (Fig. A -3).
2. Screw the elbow nipple (Fig. B -11) with seal
ring (Fig. B -12) onto the connecting nipple
(Fig. B -13) and turn the elbow nipple in the
desired direction.
3. Fix a pressure line (Fig. B -10) to the elbow
nipple (Fig. B -11).
4. Open all closing off devices (valves, spray
nozzles, water cock) in the pressure line.
14

STARTUP

Check the air pressure in the storage vessel.
CAUTION!
The house water system must only be
commissioned with a diaphragm storage
vessel pressure of 1.5 - 1.7 bar. Before
commissioning, check the air pressure at
the valve on the back of the storage ves-
sel.
1. Open the cover on the back of the storage
vessel.
2. Check the air pressure at the valve with an air
pump or a tyre pump with pressure indicator.
3. If necessary, correct the air pressure to 1.5 -
1.7 bar.
4. Then close the cover again on the back of the
storage vessel.
5. The house water system can now be commis-
sioned.
Fill the house water system
CAUTION!
Before using the house water system
each time, you must fill it with water up
to the overflow so that it can draw water
immediately. The pump will be destroyed
if it runs dry.
1. Open the filling screw (Fig. A -2).
Not with INOX
2. Use the filling screw to fill up with water until
the pump housing is full.
3. Screw the filling screw back in place.
Switch the pump on.
1. Open one of the closing off devices (valve,
spray nozzle, water cock) in the pressure line
(Fig. B -10).
2. Insert the mains plug on the connection cable
into the plug socket.
The pump starts to convey.
3. When there is no more air in the water that
comes out , close the closing off device in the
pressure line.
The pump switches off automatically af-
ter the switch-off pressure has been re-
ached. The house water system is ready
for use.