AM 30 RA/RB ROOM SENSORS

The room sensor (optional) should be mounted at a
place that has an average temperature of the hou-
se. It must not be placed where it can be affected by
direct sunshine, heat radiation or draught.
The room sensor is delivered with 15 m wire.
AM 30 RA is designed for AUTOMIX 30 E. The night
setback is programmed with switch A on the room
sensor. The yellow and green LEDs indicate night
setback and day program respectively. A setback
period can start anytime. To program night setback,
switch A has to be set from 0 to either 7 or 9 at the
time the setback is to be initiated. To obtain e.g. a
7 hour setback starting at 10.00 PM (22.00) switch
A is set from 0 to 7 at 10.00 PM (22.00). The setback
temperature will now last for 7 hours until 5.00 AM
(05.00) and then return to normal day temperatu-
re. Once set, the night setback will repeat every 24
hours, until another setting is programmed. N.B.To
change a setback period switch A is to be set first
on 0 and then on desired setback period.
After a power failure during a setback period the
yellow and green LEDs start flashing alternatingly.
In this case the night setback has to be re-program-
med.
The room temperature can be reduced by 1°, 2° or
3°C with switch B.
AM 30 RB is designed for AUTOMIX 30 Q and D. The
green and yellow LEDs indicate day- and night set-
back program respectively.
AM 30 RC REMOTE CONTROL
AM 30 RC remote control is designed for floor-
heating systems. The remote control has the same
function as knob F on the controller i.e. parallel
displacement of the regulating graph. With the re-
mote control the supply water temperature can be
lowered by 9ºC and risen by 6°C.

AM 30 PC PUMP CONTROL

AM 30 PC pump control shuts off the pump as soon
as the outdoor temperature reaches the selected
setting +15°C... +25°C. A green LED indicates
pump off. An interval control starts pump and mi-
xing valve for a short period once every 48 h.