GRAPH SETTING
The regulating graph for a certain house is depen-
dent on dimensions, location, insulation etc. There-
fore it is not possible to decide on a graph in advan-
ce. It has to be tried out.
The graph is set with knobs D and F. The knobs
work steplessly.
Starting values
Regulating graph for radiator heating, set knob D
on 6. Regulating graph for floor heating,set knob D
on 3.
Room temperature setting
Knob F grading ±10°C me¬ans that the supply wa-
ter temperature can be raised or lowered by 10°C
from setting 0. 2,5ºC supply water temperature cor-
respondes to 1ºC room temperature. Use knob F to
find the wanted room temperature.
Adjustments
If the room temperature rises with falling outdoor
temperature:
lower knob D
raise knob F
If the room temperature falls with falling outdoor
temperature:
raise knob D
lower knob F
Make only very small changes with knobs D and F.
When the house has an even temperature despite
fluctuating outdoor temperatures, the cor¬rect re-
gulating graph has been obtained.
N.B! Heat affects slowly. When the temperature set-
ting has been changed it takes several hours before
the room temperature corresponds to the new set-
ting due to dimensions of the heating system and
the insulation of the house. A floor heating system
responds even slower to a new setting than a ra-
diator system.
REGULATING GRAPH
NIGHT SETBACK PROGRAMMING
AUTOMIX 30 E has an electronic programmer with
24 h program facility for night setback once in a 24
h period. The setback period is 7 hours. To program
night setback, the program selector has to be swit-
ched from day temperature to setback temperature
at the time the setback is to be initiated. The setback
can start anytime. For example, if the setback period
is to start at 10.00 PM (22.00) the pro-ram selector is
switched from day temperature to setback tempe-
rature at 10.00 PM. (22.00)The setback temperature
will now last for 7 hours until 5.00 AM (05.00) and
then return to normal room temperature. Once set,
the setback period will repeat every 24 hours, until
another setting is pro-grammed. In case of a power
failure during the setback period the yellow and
green LEDs start flashing alternatingly. In this case
the night setback has to be re-programmed.
The setback temperature is selected with knob H.
Knob H grading 0°-10°C me¬ans that the supply
water temperature can be lowered by 10°C from
setting 0. 2,5ºC supply water temperature corres-
pondes to 1ºC room temperature.
N.B! With a connected room sensor AM 30 RA/RB
the knob H grading means 0°–10ºC room tempe-
rature.
AUTOMIX 30 Q has a quartz programmer with day-
and weekly program facility for night setback 6 ti-
mes in a 24 h period. The programmer has 150 h
spring reserve.

Supply water
°C temperature
Outdoor temperature