The water softener should be adjusted
according to the hardness of the water in
your area. Your local water authority can
advise you on the hardness of the water
Water hardness
German de‐
French de‐
grees (°dH)
grees (°fH)
47 - 50
84 - 90
43 - 46
76 - 83
37 - 42
65 - 75
29 - 36
51 - 64
23 - 28
40 - 50
19 - 22
33 - 39
15 - 18
26 - 32
11 - 14
19 - 25
4 - 10
7 - 18
<4
1) Factory setting.
2) Do not use salt at this level.
Regardless of the type of detergent
used, set the proper water hardness
level to keep the salt refill indicator
active.
Multi-tabs containing salt are
not effective enough to
soften hard water.
Regeneration process
For the correct water softener operation,
the resin of the softener device needs to
be regenerated regularly. This process is
automatic and is the part of the normal
dishwasher operation.
When the prescribed quantity of water
(see values in the table) has been used
since the previous regeneration process,
a new regeneration process will be
initiated between the final rinse and the
programme end.
mmol/l
8.4 - 9.0
7.6 - 8.3
6.5 - 7.5
5.1 - 6.4
4.0 - 5.0
3.3 - 3.9
2.6 - 3.2
1.9 - 2.5
0.7 - 1.8
<7
<0.7
in your area. Set the right level of the
water softener to assure good washing
results.
mg/l (ppm)
Clarke
degrees
835 - 904
58 - 63
755 - 834
53 - 57
645 - 754
46 - 52
505 - 644
36 - 45
395 - 504
28 - 35
325 - 394
23 - 27
255 - 324
18 - 22
185 - 254
13 - 17
70 - 184
5 - 12
<70
< 5
Water softener lev‐
el
1
2
3
4
5
6
7
8
9
10
In case of the high water softener setting,
it may occur also in the middle of the
programme, before the rinse (twice
during a programme). Regeneration
ENGLISH
13
Water softener
level
10
9
8
7
6
1)
5
4
3
2
2)
1
Amount of water
(l)
250
100
62
47
25
17
10
5
3
3

Werbung