Herunterladen Inhalt Inhalt Diese Seite drucken

Safety Instructions; Maintenance Instructions - Harvia SGC0909BR Montageanleitung Und Bedienungsanleitung

Radiant serie
Vorschau ausblenden Andere Handbücher für SGC0909BR:
Inhaltsverzeichnis

Werbung

eN
A
B
Plug the infrared cabin into a proper wall outlet. Do not
share the outlet with any other appliances. The infrared
cabin should be unplugged when not in use. After 2 hours
of continuous use, switch the cabin off for one hour.
Otherwise the components' working life may shorten.
A. Switch the infrared cabin on/off.
B. Set the desired temperature.
Press and hold to make the value change faster.
C. Set the desired on-time.
Press and hold to make the value change faster.
The range is 5–60 minutes.
When there is 5 minutes left, the control unit will
sound an alarm.
The cabin will switch off automatically after the
on-time has run out.
D. Switch the light on/off.
e. Adjust air circulation in the cabin.
Change the unit of temperature (°C/°F)
Press and hold simultaneously the buttons "+" and "–" ,
then press "Light" to change.
error messages
error message in the
temperature display
eP
H
00
(infrared cabin does not heat)
16
INSTRUCTIoNS FoR USe

Safety Instructions

Maintenance Instructions

Description
Temperature sensor failure.
Temperature in the infrared cabin
too high.
Radiator failure.
D
C
To avoid the risk of fire, do not dry clothes or leave
any towels in the infrared cabin.
To prevent burns or electric shocks, do not touch or
use metal tools on the radiators.
The light bulb heats in use. If the bulb needs to be
changed, unplug the cabin and let the bulb cool
down before changing it.
Do not spray water on the radiators. T his may result
in electric shock or damage to the radiators.
Do not let young, handicapped or ill people use the
cabin on their own.
Consult your doctor about any health-related
limitations to using the cabin.
Never go to a hot infrared cabin if you have taken
alcohol, strong medicines or narcotics.
Clean the cabin with a damp cotton towel, dry with
a clean dry towel.
Do not use strong cleaning chemicals on the cabin.
Remedy
Check the wires to the temperature sensor
and their connections for faulties. Replace
the sensor.
Switch off the infrared cabin and let it cool
down.
Check the functioning of the radiators.
Change any broken radiators.
E

Werbung

Inhaltsverzeichnis
loading