Commissioning (qualified contractors)

Property damage
The appliance is designed for undersink installation.
u During installation, the water connections on the
appliance must point upwards.
Ensure that the appliance is freely accessible for
maintenance work.
Always install the appliance vertically and near the draw-off
point.
D0000105763
5.2

Appliance installation

u Mark out the holes for drilling using the installation tem-
plate.
u Drill the holes and insert suitable rawl plugs.
u Secure the wall mounting bracket using suitable screws.
u Hang the appliance on the wall mounting bracket.
u Surplus connecting cable can be stored in the cable storage.
D0000105765
5.3

Water connection

Property damage
The appliance may develop a leak and cease function-
ing.
u Never subject the appliance to water pressure.
u Never interchange the water connections.
u Set the flow rate (see tap instructions). Observe
the maximum permissible flow rate with a fully
opened tap (see chapter "Specification / Data
table").
14
| SNU 10 Plus
NOTICE
NOTICE
u Match up the colour coding on the tap water connections
and the appliance:
– R.h. side blue = "Cold water inlet"
– L.h. side red = "DHW outlet"
u Secure the water connections from the tap to the appliance.
D0000105764
NOTICE:  When tightening the fittings, counterhold with a suit-
able spanner.
NOTICE: Ensure that the water connections are not kinked dur-
ing installation. Prevent any tensioning during installation.
6
Commissioning (qualified contract-
ors)
NOTICE: Do not connect the power supply until the appliance is
completely filled with water!
WARNING
Electrocution
Incorrect installation and commissioning can cause
serious injury.
u Commissioning may only be carried out by a
qualified contractor in accordance with safety
regulations.
6.1

Filling the appliance with water

1.
D0000049325
u Open the cold water inlet of the distribution board.
u Either open the DHW valve of the tap or set the mono lever
mixer tap to "hot" until the water that flows out is free of air
bubbles. This process may take several minutes.
u Check the entire hydraulic installation for tightness.