Herunterladen Inhalt Inhalt Diese Seite drucken

Operating The Product - Dimplex Pro-Serie Bedienungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 12
3. Slide the appliance into the fireplace mantle fully from the back ensuring that it is sitting in the center of the mantle. Using
suitable screws (not supplied) screw fix the appliance in place (Fig 20)
4. Be sure to position the fireplace within 1m of a power outlet (Fig 21)
Installation into a wall or recess cavity
1. Note the product dimensions in Fig 1 and build a suitable structure for the appliance to fit into within 1m of a power outlet
(Fig 22). Using suitable screws (not supplied) screw fix the appliance in place
2. Note the venting slots in the appliance. There are located at the front base and under the appliance
3. Build the wall up against the appliance using the spacing brackets as a guide.
4. There is to be an air vent at the front of the structure of at least 88cm2. It is essential to ensure that air can circulate
into the appliance – otherwise the Opti-myst flame effect will not operate correctly. This pathway for air must not be
obstructed. For examples of air vents in a wall or recess cavity see Fig 23
Connecting the Transducer Unit + Lamps
1. Release the two red tabs by turning them by 90 degrees (Fig 2)
2. Lift out the Sump Nozzle (Fig 3)
3. Insert lamps into lamp holders (Fig 4), carefully locating the pins into the holes (Fig 4a)
4. Push lamps firmly into place
5. Place the Transducer Unit into the sump and join the cable to the connector on the sump (Fig 5)
6. To ensure that the Transducer Unit is correctly placed in the sump, the tab on the Transducer Unit should be lined up with
the moulded recess in the sump (Fig 5a).
7. Ensure that the cable is not placed above the disc on the Transducer Unit (Fig 5b). To prevent the cable becoming
pinched between the nozzle and the sump, place the cable in the slot in the wall of the sump.
8. Replace the Sump Nozzle and secure it by turning the two red tabs by 90 degrees (Fig 6)
Filling the Water Tank
9. Place Water Tank in sink and remove cap (turn anti-clockwise to open) (Fig 7)
10. Fill Water Tank with filtered tap water only. This is necessary to prolong the life of the flame and smoke producing unit.
The water should be filtered through a conventional domestic water filter unit and the filter should be replaced regularly.
Distilled water must not be used.
11. Screw the cap back on – do not overtighten.
12. Place the Water Tank in the Sump, with the tank cap facing down and the flat side of the tank facing outward (Fig 8)
Assembling the fire
13. Place the Fuelbed on top of the Water Tank and Mist Nozzle (Fig 9)

Operating the Product

WARNING: FAILURE TO FOLLOW THESE OPERATING INSTRUCTIONS MAY RESULT IN INJURY AND/OR DAMAGE.
Manual Controls
The Opti-myst Manual controls are located on the base of the appliance.
(See Fig. 10 for Manual Control layout)
Switch 'A':- Controls the electricity supply to the Fire.
Note: This switch must be in the 'ON' (I) position for the Fire to operate with or without heat when activated.
Switch 'B':- Press
once to turn on the flame effect. This will be indicated by an audible "beep". Although the main lights
operate immediately it will take a further 45 seconds before the flame effect starts.
Press
to put fire into standby mode. This will be indicated by one "beep".
Remote Control
The remote control is packed with 2 AA batteries in a bag. Lift off the battery cover on the back of the remote control and
insert the batteries taking note of the polarity.
The remote control has already been paired to your product during factory assembly. In the unlikely event that the remote
control disconnects from the product, or you obtain a spare remote control, you will need to complete the pairing pro-
cess:
1. With the product plugged in press switch A to the ON (I) position. You should hear an audible beep
2. Press and hold 'Button 6' until PAIR appears on the display
3. Bring the remote control close to the product where the receiver is
4. The product will start to beep and blink
5. Press 'Button 6' to complete the pairing process. The product will go into standby mode.
Switching on the appliance
. See Fig 17
3

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Pro eng56-400Pro eng68-400Pro eng56-600

Inhaltsverzeichnis