Herunterladen Inhalt Inhalt Diese Seite drucken

Battery Warnings For Active Version - Simons Voss Technologies Z4.PL Kurzanleitung

Vorhangschloss
Vorschau ausblenden Andere Handbücher für Z4.PL:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 3
All manuals and user guides at all-guides.com
– Battery Warning Level 2: 8 short audible signals for
30 seconds + LED flashes red briefly twice with a
one-second break between each signal. Indicates
emergency battery warning: Batteries are almost
completely empty. Replace batteries in the padlock
immediately.
– 8 short audible signals after disengaging indicate
that the transponder battery is empty. Have
transponder battery replaced.
After Battery Warning Level 2 is emitted for the first time,
it is still possible
– Active padlock: about 50 opening transactions are
carried out.
– (Passive) padlock: about 200 opening transactions
are carried out.
After reaching this number of opening transactions or
after about 4 weeks (active) / about 2 weeks (passive/
SC), the padlock automatically switches to
– G1: emergency battery storage mode
– G2: freeze mode
Once this warning level is reached, only the locking sys-
tem administrator is able to gain access. User transpon-
ders are no longer accepted (consult 'Battery warnings' in
the locking cylinder manual for more detailed information).

6 Battery warnings for active version

1. Place the installation/battery key on the knob in such
a way that its two teeth lock into the openings in the
locking disc; If necessary, turn the knob until both
teeth engage into the knob. Important: the battery/in-
stallation key must be placed flat on the inside front
surface of the recessed grip ring to ensure that the
installation tool can engage into the locking disc.
2. Hold the knob firmly and carefully turn the battery/in-
stallation key about 30° in a clockwise direction (until
you hear a click).